CDM-Qx Satellite Modem

Remote Control

 

 

 

 

Command

 

 

Arguments

 

 

 

 

 

 

for

 

Parameter

 

 

(Instruction

 

 

 

 

 

 

 

Command or

 

Type

 

 

Code and

 

 

 

 

 

 

 

Response to

 

 

 

 

qualifier)

 

 

 

 

 

 

 

 

Query

 

 

 

 

 

 

 

Revision 4

MN/CDMQx.IOM

 

 

 

 

Response to

 

 

Query

 

 

Response to query

 

 

Description of arguments

 

 

Command

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

 

(Target to

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

Controller)

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUC Output

BOE=

Enable

 

(L-Band Unit

 

only)

 

BUC High

BCH=

Current Limit

 

(L-Band Unit

 

only)

 

 

 

BUC Low

BCL=

Current Limit

 

(L-Band Unit

 

only)

 

 

 

BUC LO

BLO=

Frequency

 

(L-Band Unit

 

only)

 

BUC Output

N/A

Power Level

 

(L-Band Unit

 

only)

 

1 byte, value of 0,1

4bytes

4bytes

6bytes

4 bytes

Command or Query

BOE=

BOE?

BOE=x

Indicates BUC Output enable

BOE?

 

(see description of

0=Off (Output Disabled)

BOE*

 

arguments)

1=On(Output Enabled)

BOE#

 

 

Example: BOE=1 (BUC Output is Enabled)

BOE^

 

 

 

 

 

Note: This command is only valid when the BUC FSK comms

 

 

 

and BUC power are enabled.

 

 

 

 

 

 

 

Command or Query

BCH=

BCH?

BCH=xxxx

BUC High Current Limit, a value between 500 and 3200 mA

BCH?

 

(see description of

 

BCH*

 

arguments)

Example: BCH=3100

BCH#

 

 

 

BCH^

 

 

Command or Query

BCL=

BCL?

BCL=xxxx

BUC Low Current Limit, a value between 100 and 3000 mA

BCL?

 

(see description of

 

BCL*

 

arguments)

Example: BCL=0600

BCL#

 

 

 

BCL^

 

 

Command or Query

BLO=

BLO?

BLO=xxxxxs

BUC transmit LO frequency information in the form: xxxxxs,

BLO?

 

(see description of

where :

BLO*

 

arguments)

xxxxx is the LO frequency in the range of 3000 to 65000 MHz

BLO#

 

 

All 0’s (000000) disables the feature

BLO^

 

 

S is the sign for the mix (+ or – character)

 

 

 

Terminal Frequency= BUC LO TFQ

 

 

 

Example: BLO=12000+ (BUC LO is 12 GHz, low-side mix)

 

 

 

 

 

 

 

Query only

N/A

BOL?

BOL=xx.x

BUC output power level in the form xxx, where xxx is the value

 

 

(see description of

in watts.

 

 

arguments)

Example: BOL=08.3 (BUC reports output is 8.3 watts)

 

 

 

Returns 00.0 when FSK and BUC power are not enabled.

 

 

 

 

 

 

 

C-43

Page 233
Image 233
Mocomtech CDM-QX Buc Lo Blo=, Boe= Boe?, Boe#, Bch= Bch?, Bch#, Bcl= Bcl?, Bcl#, Blo= Blo?, Blo#, Bol?