Front Panel Operation

MN/CDMQx.IOM

If Upper is selected, the following sub-menu is displayed:

BUC Current Alarm Upper

Limit:1200mA

(◄ ►,▲▼, ENT)

Edit the BUC Current Alarm Upper limit. This is accomplished by selecting the digit to be edited, using the WXarrow keys. The value of the digit is then changed using the STarrow keys. The user should then press ENT. The range of current is from 500 to 4000 mA.

If Lower is selected, the following sub-menu is displayed:

BUC Current Alarm Lower

Limit:1200mA

(◄ ►,▲▼, ENT)

Edit the BUC Current Alarm Lower limit. This is accomplished by selecting the digit to be edited, using the WXarrow keys. The value of the digit is then changed using the STarrow keys. The user should then press ENT. The range of current is from 100 to 3000 mA.

(Config„ODU„BUC„Delay) - BUC DELAY

If Delay is selected, the following sub-menu is displayed:

BUC

Power-On Delay:

001

seconds

(◄ ►▲ ▼ ENT)

Edit the value of the power-on delay. This is accomplished by selecting the digit to be edited, using the WXarrow keys. The value of the digit is then changed using the STarrow keys. The user should then press ENT. The valid range is from 0 to 999 seconds.

5–48

Page 102
Image 102
Mocomtech CDM-QX Config„ODU„BUC„Delay BUC Delay, BUC Current Alarm Upper Limit1200mA, BUC Current Alarm Lower Limit1200mA