Mocomtech CDM-QX operation manual Monitor„ODU Monitor ODU for L-Band Unit only, Odu Lnb

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 114
Image 114

CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

5.6.2.7(Monitor„ODU) – MONITOR ODU (for L-Band Unit only)

If ODU is selected, the following sub-menu is displayed:

Outdoor

Unit Monitor:

ODU LNB

(◄ ►, ENT)

If BUC is selected, the following menu is displayed:

BUC: DC=47.8V,3.2A T=38oC

SW=1.1 PLL=Flt Pwr=02.1W

The menu displays the following parameters:

DC Pwr

(DC Power) If a BUC supply is installed, displays

 

measured BUC supply voltage and load current,

 

measured at the Tx-IF connector.

T

(Temperature) If BUC FSK is enabled, displays

 

BUC ambient temperature in °C.

SW

If BUC FSK is enabled, displays the M&C

 

software version of the BUC.

PLL

If BUC FSK is enabled, displays the fault status of

 

the BUC PLL synthesizers.

Pwr

(Output) If BUC FSK is enabled, displays the

 

output power as measured by the BUC power

 

monitor.

Press ENT or CLR to return to the next-highest menu.

Select LNB or BUC, using the ◄ ► arrow keys, then press ENT.

If LNB is selected, the following menu is displayed:

LNB

Voltage:

13.1 volts

(ENT)

LNB

Current:

235 mA

The menu displays the LNB Voltage and Current. Press ENT or CLR to return to the next-highest menu.

5–60

Page 114
Image 114
Mocomtech CDM-QX operation manual Monitor„ODU Monitor ODU for L-Band Unit only, Odu Lnb