Mocomtech CDM-QX Mode Config, Spectrum Analyzer Mode, Spectrum Analyzer ,ENT Span = 12.5 MHz

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 118
Image 118

CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

If Spec-Analyzeris selected:

 

Spectrum Analyzer:

(◄ ►, ENT)

 

Mode Config

Selecting Mode will display:

 

 

 

 

 

 

Spectrum Analyzer Mode:

►, ENT)

 

Off On

(

This menu allows the user to turn ON or OFF the engine of the spectrum analyzer. If spectrum analyzer mode is ON, the user can use Comtech’s application software (Windows) to view the spectrum, or use the Web browser.

Selecting Config will display:

Config Spectrum Analyzer:

CenterFreq Span

(◄ ►, ENT)

If CenterFreq is selected:

Spectrum Analyzer: (◄ ►,▲▼,ENT)

Center Freq = 0070.0000 MHz

The Center Freq is similar to Rx Frequency in a regular demodulation function with a resolution of 100 Hz.

If Span is selected:

Spectrum Analyzer: (▲▼,ENT)

Span = 12.5 MHz

The user can only select the following predefined span values:

97.65625 kHz

781.25 kHz

6.25 MHz

195.3125 kHz

1.5625 MHz

12.5 MHz

390.625 kHz

3.125 MHz

 

Default is 12.5 MHz.

5–64

Page 118
Image 118
Mocomtech CDM-QX operation manual Mode Config, Spectrum Analyzer Mode, Config Spectrum Analyzer CenterFreq Span