Mocomtech CDM-QX operation manual Buc, But?, Bpa?, Bsv?, Bdc?

Models: CDM-QX

1 258
Download 258 pages 16.72 Kb
Page 234
Image 234

CDM-Qx Satellite Modem

Remote Control

 

 

 

 

Command

 

 

Arguments

 

 

 

 

 

 

for

 

Parameter

 

 

(Instruction

 

 

 

 

 

 

 

Command or

 

Type

 

 

Code and

 

 

 

 

 

 

 

Response to

 

 

 

 

qualifier)

 

 

 

 

 

 

 

 

Query

 

 

 

 

 

 

 

 

 

Revision 4

 

 

 

 

 

 

 

 

 

MN/CDMQx.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response to

 

 

Query

 

 

Response to query

 

 

Description of arguments

 

 

Command

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

 

(Target to

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

Controller)

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUC

N/A

Temperature

 

(L-Band Unit

 

only)

 

BUC PLL Alarm

N/A

(L-Band Unit

 

only)

 

BUC Software

N/A

Version

 

(L-Band Unit

 

only)

 

 

 

BUC Current

N/A

(L-Band Unit

 

only)

 

4 bytes

1 byte, value of 0,1

3bytes

4bytes

Query only

N/A

BUT?

BUT=sxx

Indicates BUC temperature, in the form: sxxx

 

 

(see description or

Where:

 

 

arguments)

s=sign (+ or – character)

 

 

 

xx=value

 

 

 

If not available, response is –99

 

 

 

Example: BUT=-13 (BUC temperatures is -13°C)

 

 

 

Note: This query is only valid when the FSK and BUC power

 

 

 

are turned On.

 

 

 

 

 

 

 

Query only

N/A

BPA?

BPA=x

BUC PLL lock state, where:

 

 

(see description of

0=Unlocked

 

 

arguments)

1=Locked

 

 

 

Example: BPA=1 (BUC PLL is locked)

 

 

 

Note: This query is only valid when the FSK and BUC power

 

 

 

are turned On

 

 

 

 

 

 

 

Query only

N/A

BSV?

BSV=x.x

Indicates the BUC software version, in the form: x.x

 

 

(see description of

Example: BSV=1.1 (Software version 1.1)

 

 

arguments)

 

 

 

Note: This query is only valid when the FSK and BUC power

 

 

 

are turned On

 

 

 

 

 

 

 

Query only

N/A

BDC?

BDC=xxxx

Indicates the value of the BUC Current, in the form: xxxx,

 

 

(see description of

where: xxxx is between 0 and 9999, units MA.

 

 

arguments)

If not available, response is 0000

 

 

 

Example: BDC=3100

 

 

 

 

 

 

 

C-44

Page 234
Image 234