CDM-Qx Satellite Modem

Revision 5

Installation

MN/CDMQx.IOM

2.2Mounting

If the modem is to be mounted in a rack, ensure that there is adequate clearance for ventilation, particularly at the sides. In rack systems where there is high heat dissipation, forced air-cooling must be provided by top or bottom mounted fans or blowers. Under no circumstance should the highest internal rack temperature be allowed to exceed 50°C (122°F).

2.2.1Optional Rear-Mounting Installation Bracket

Install optional installation brackets (Figure 2-1) using mounting kit KT/6228-2:

Mounting Kit KT/6228-2 (Optional)

Quantity

Part Number

Description

 

 

 

2

HW/10-32SHLDR

Screw, #10 Shoulder

4

HW/10-32FLT

Washer, #10 Flat

2

HW/10-32SPLIT

Washer, #10 Split

2

HW/10-32HEXNUT

Nut, #10 Hex

2

FP/6138-1

Bracket, Rear Support

4

HW/10-32x1/2RK

Bolt, #10 Rack Bracket

The tools required for this installation are a medium Phillipsscrewdriver and a 5/32-inch SAE AllenWrench.

The CDM-QD is assembled into the equipment rack as shown in Figure 2-1:

Step

1

2

3

Procedure

Secure the #10 shoulder screws to the unit chassis through the rear right and left side mounting slots, using the #10 flat washers, #10 split washers, and #10 hex nuts as shown.

Install the rear support brackets onto the equipment rack threaded rear mounting rails, using the #10 bracket bolts.

Mount the unit into the equipment rack, ensuring that the shoulders of the #10 shoulder screws properly engage into the rear support bracket slots.

2–2

Page 34
Image 34
Mocomtech CDM-QX operation manual Optional Rear-Mounting Installation Bracket