CDM-Qx Satellite Modem

 

 

 

 

 

Revision 4

 

 

 

 

 

 

 

 

Remote Control

 

 

 

MN/CDMQx.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

Arguments for

 

 

 

 

 

Response

 

 

Query

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

Response to query

 

 

Parameter

 

 

(Instruction

 

 

Command or

 

 

Description of Arguments

 

 

 

 

(Instruction

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

 

 

 

(Target to

 

 

Type

 

 

Code and

 

 

Response to

 

 

 

 

 

 

 

Code and

 

 

 

 

 

 

 

 

 

 

 

 

 

(Target to

 

 

 

 

Controller)

 

 

 

 

 

qualifier)

 

 

Query

 

 

 

 

 

 

 

Qualifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Type

 

 

N/A

 

11 bytes

 

Query only. Syntax: Who=aw,bx,cy,dz

 

 

N/A

 

 

WHO?

 

WHO=aw,bx,cy,dz

 

 

 

 

 

 

 

 

 

 

Type of plug-in:

 

 

 

 

 

 

 

(see description of

 

 

 

 

 

 

 

 

 

 

Where:

 

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

a,b,c,d

w,x,y,z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0=unoccupied

0=unoccupied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=transmit

1=70/140 MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2=receive

2=L-Band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3=Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4=Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

aw=slot#1, bx=slot#2, cy=slot#3, dz=slot#4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: WHO=00, 11, 21, 00, (slot#1=empty,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

slot#2=Tx, slot#3=Rx, slot#4=empty. Both Tx and Rx are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70/140 MHz cards)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Eb/No

 

 

N/A

 

4 bytes

 

Query only

 

 

N/A

 

 

REB?

 

REB=xx.x

 

 

(Modem only)

 

 

 

 

 

 

 

Returns the value of Eb/No of the remote demod

 

 

 

 

 

 

 

(see description of

 

 

 

 

 

 

 

 

 

 

Responds 99.9=remote demod unlock

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

Responds xx.x if EDMAC is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xx.x=02.0 to 16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: REB=12.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: for values > 16.0 dB, the reply will be 16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX Power Level

 

 

N/A

 

3 bytes

 

Query only.

 

 

N/A

 

 

PLI?

 

PLI=x.x

 

 

Increase

 

 

 

 

 

 

 

Returns the increase in TX power level, in dB (from the

 

 

 

 

 

 

 

(see description of

 

 

(Modem only)

 

 

 

 

 

 

 

nominal setting) due to the action of AUPC. Range is 0.0

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

to 9.9 dB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Responds x.x if AUPC is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: PLI=2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C-33

Page 223
Image 223
Mocomtech CDM-QX operation manual Who?, Reb?