CDM-Qx Satellite Modem

Revision 5

Front Panel Operation

MN/CDMQx.IOM

Log 023: 30/11/02 10:37:32

Fault - Demod Lock (3) (▲▼,ENT)

In this example, the demodulator installed in slot #3 is faulted on Nov. 30, 2002 at 10:37:32 with log number 23.

(Monitor„Event-Log„View) – VIEW STORED EVENTS

The user may scroll backwards or forwards through the entries in the event log, using the STarrow keys. Pressing ENT or CLR will take the user back to the previous menu. The event log can store up to 255 events. When a fault condition occurs, it is time-stamped and put into the log. Similarly, when the fault condition clears, this is also recorded, as shown below:

Log 024: 30/11/97 10:37:35

Clear - Demod Lock (3) (▲▼,ENT)

If the user selects Clear-All, the event log is cleared, and the user is taken directly back to the previous menu. However, if there are faults present on the unit at this time, they will be re-time-stamped, and new log entries will be generated.

IMPORTANT: Note that in accordance with international convention, the date is shown in DAY-MONTH-YEAR format.

IMPORTANT

5–56

Page 110
Image 110
Mocomtech CDM-QX operation manual Monitor„Event-Log„View View Stored Events, Log 023 30/11/02 Fault Demod Lock 3 ,ENT