A P P E N D I X A | Intel® NetStructure™ 7190 |
Power Indication
The front panel Power LED connects directly to the unit’s power supply. If the Power LED is not illuminated, power is not connected to the unit, or the unit’s power supply has failed.
Boot-time LED Diagnostics
The front panel’s Status, Act 1 and Act 2 LEDs display the transition through a sequence of codes at boot time indicating the product’s progress through the boot process. If the boot process aborts, terminates, or halts before the product is online and functional, the state of the LEDs can help in diagnosing the problem. The following table describes the startup sequence and conditions.
|
|
|
| Console |
Status | Act 1 | Act 2 | Condition | Message |
|
|
|
|
|
Off | Off | Off | BIOS boot failed |
|
|
|
|
|
|
On | Off | Off | OS boot process failed | Starting OS…. |
|
|
|
|
|
Off | On | Off | OS boot stage 1 failed | OS Phase 1…. |
|
|
|
|
|
On | On | Off | OS boot stage 2 failed | OS Phase 2…. |
|
|
|
|
|
Off | Off | On | OS boot stage 3 failed | OS Phase 3…. |
|
|
|
|
|
On | Off | On | Application never started up |
|
|
|
|
|
|
Off | On | On | Application restart stage 1 failed |
|
|
|
|
|
|
On | On | On | Application restart stage 2 failed |
|
Boot-Time LED Diagnostics
After restart completes, the Status LED begins to blink and LED activity begins as described in the next section, “Runtime LED Diagnostics.”
150