A P P E N D I X A

Intel® NetStructure™ 7190 Multi-Site Traffic Director User Guide

Power Indication

The front panel Power LED connects directly to the unit’s power supply. If the Power LED is not illuminated, power is not connected to the unit, or the unit’s power supply has failed.

Boot-time LED Diagnostics

The front panel’s Status, Act 1 and Act 2 LEDs display the transition through a sequence of codes at boot time indicating the product’s progress through the boot process. If the boot process aborts, terminates, or halts before the product is online and functional, the state of the LEDs can help in diagnosing the problem. The following table describes the startup sequence and conditions.

 

 

 

 

Console

Status

Act 1

Act 2

Condition

Message

 

 

 

 

 

Off

Off

Off

BIOS boot failed

 

 

 

 

 

 

On

Off

Off

OS boot process failed

Starting OS….

 

 

 

 

 

Off

On

Off

OS boot stage 1 failed

OS Phase 1….

 

 

 

 

 

On

On

Off

OS boot stage 2 failed

OS Phase 2….

 

 

 

 

 

Off

Off

On

OS boot stage 3 failed

OS Phase 3….

 

 

 

 

 

On

Off

On

Application never started up

 

 

 

 

 

 

Off

On

On

Application restart stage 1 failed

 

 

 

 

 

 

On

On

On

Application restart stage 2 failed

 

Boot-Time LED Diagnostics

After restart completes, the Status LED begins to blink and LED activity begins as described in the next section, “Runtime LED Diagnostics.”

150

Page 158
Image 158
Intel 7190 manual Power Indication, Boot-time LED Diagnostics, Boot-Time LED Diagnostics