A P P E N D I X AIntel® NetStructure 7190 Multi-Site Traffic Director User Guid e
150
Power Indication
The front panel Power LED connects directly to the units power
supply. If the Power LED is not illuminated, power is not connected
to the unit, or the units power supply has failed.

Boot-time LED Diagnostics

The front panels Status, Act 1 and Act 2 LEDs display the transition
through a sequence of codes at boot time indicating the products
progress through the boot process. If the boot process aborts,
terminates, or halts before the product is online and functional, the
state of the LEDs can help in diagnosing the problem. The following
table describes the startup sequence and conditions.
After restart completes, the Status LED begins to blink and LED
activity begins as described in the next section, Runtime LED
Diagnostics.
Status Act 1 Act 2 Condition Console
Message
Off Off Off BIOS boot failed
On Off Off OS boot process failed Starting OS.
Off On Off OS boot stage 1 failed OS Phase 1.
On On Off OS boot stage 2 failed OS Phase 2.
Off Off On OS boot stage 3 failed OS Phase 3.
On Off On Application never started up
Off On On Application restart stage 1 failed
On On On Application restart stage 2 failed
Boot-Time LED Diagnostics