Motorola QIP7000 installation manual Diagnostics, Field, Description, Error Code, 574702-001 a

Models: QIP7000

1 86
Download 86 pages 50.12 Kb
Page 45
Image 45
Field

Diagnostics

The General Status fields are:

B

 

 

 

 

 

 

 

 

Field

 

Description

 

 

 

 

 

 

 

 

 

 

Error

Error codes display on the front panel and OSD when an error occurs. If multiple errors

 

 

 

 

occur, the last recorded error is displayed:

 

 

 

 

 

 

 

 

 

 

Error Code

Description

 

 

 

 

 

 

 

 

 

 

EP00

No error

 

 

 

 

 

 

 

 

 

 

EP01

Not connected

 

 

 

 

 

 

 

 

 

 

EP03

DRAM error

 

 

 

 

 

 

 

 

 

 

EP04

SRAM error

 

 

 

 

 

 

 

 

 

 

EP07

ROM verification failure

 

 

 

 

 

 

 

 

 

 

EP08

RAM test failure

 

 

 

 

 

 

 

 

 

 

EP09

Battery test failure

 

 

 

 

 

 

 

 

 

 

EP11

Invalid unit address

 

 

 

 

 

 

 

 

 

 

EP12

Power on self test failure

 

 

 

 

 

 

 

 

 

 

EP14

GITV startup failure

 

 

 

 

 

 

 

 

 

 

EP15

TSI structure corrupt

 

 

 

 

 

 

 

 

 

 

EP18

Driver initialization failure

 

 

 

 

 

 

 

Connected State

 

A QIP-operations connect or disconnect message determines whether the QIP7000

 

 

 

 

series is CONNECTED or DISCONNECTED.

 

 

 

 

 

 

Platform ID

A unique, 16-bit hexadecimal number that identifies the platform image (also called the

 

 

 

 

ROM ID).

 

 

 

 

 

 

 

 

Family ID

 

The manufacturer and product family, in hexadecimal.

 

 

 

 

 

 

 

Model ID

 

The model, in hexadecimal.

 

 

 

 

 

 

 

Remod Chan

 

The interface to the subscriber TV; channel 3 or 4 in the USA.

 

 

 

 

 

 

Set-top Time

The current OOB time displayed in global positioning system (GPS) seconds from Jan 6,

 

 

 

 

1980. It is an integer from 0 to 4294967295.

 

 

 

 

 

 

 

Decryption Mode

 

Indicates secure processor decrypt scheme:

 

 

 

 

CSA — connect scrambler algorithm

 

 

 

 

DES — Data Encryption Standard

 

 

 

 

 

 

 

 

QIP7000 (P2) Series Hybrid QAM/IP HD Set-top Terminal • Installation Manual

37

574702-001 a

This document is uncontrolled pending incorporation in a Motorola CMS

Page 45
Image 45
Motorola QIP7000 installation manual Diagnostics, Field, Description, Error Code, 574702-001 a