Image 49
Front Panel

Diagnostics

The Out-Of-Band Status fields are:

B

Field

Description

 

 

 

 

OOB Frequency

Indicates the OOB tuner center frequency, from 70 to 130 MHz.

 

 

Carrier Lock

Indicates whether the OOB receiver is locked to the carrier:

 

 

 

 

 

OSD

Front Panel

Description

 

 

 

 

 

YES

L

Carrier locked

 

 

 

 

 

NO

U

Carrier unlocked

 

 

Data

Indicates whether data is being carried by the OOB and EMM traffic, which is

 

tracked separately:

 

 

 

 

 

 

OSD

Front Panel

Description

 

 

 

 

 

YES

On

OOB data detected within last 5 seconds

 

 

 

 

 

NO

Off

OOB data not detected within last 5 seconds

 

 

EMM Data

Indicates whether EMM data is being carried on the OOB stream:

 

 

 

 

 

OSD

Front Panel

Description

 

 

 

 

 

YES

On

EMM data detected within last 5 seconds

 

 

 

 

 

NO

Off

EMM data not detected within last 5 seconds

 

 

SNR

When carrier lock has been established, displays an estimate of the carrier

 

signal-to-noise ratio in dB, with an explanation:

GOOD — Good value

FAIR — Marginal signal level, check the signal

POOR — Unusable signal

INVALID — Invalid SNR value

 

AGC

When carrier lock has been established, displays an estimate of the AGC as a

 

 

percentage, with an explanation:

 

 

GOOD — Good value

 

 

FAIR — Marginal signal level, check the signal

 

 

POOR — Unusable signal

 

 

INVALID — Invalid AGC value

 

 

 

 

 

EMM Provider ID

Displays the conditional access stream for the QIP7000 series, in hexadecimal.

 

 

 

 

 

EMM PID

Displays the packet identifier (PID) stream the QIP7000 series tunes to for EMM

 

 

data, in hexadecimal.

 

 

 

 

 

Network PID

Displays the network PID to which the QIP7000 series is tuned to receive

 

 

network messages, in hexadecimal.

 

 

 

 

 

Hunt Mode

The hunt mode includes Hunted, None, Round Robin (RR), Search (SRCH), Fixed

 

 

Frequency (FIX), or EMM Provider ID (EMM).

 

 

 

 

 

LKC

The last known carrier is the last valid OOB frequency displayed in MHz and

 

 

ranges from 70 to 130 MHz, with the specific values of: 75.25, 104.20, 72.75,

 

 

92.25, 98.25, 107.25, 107.40, 110.25, 116.25, and 103.75.

 

 

LKC will remain blank during hunting if a valid carrier has not been found, and will

 

 

be populated once a valid OOB is found.

 

 

 

 

 

Man Pag

Only displayed when QIP7000 series is not hunting and the operator presses

 

 

“menu” button. The operator can then scroll up or down to one of the specific

 

 

OOB frequencies.

 

 

 

 

 

 

 

 

 

 

QIP7000 (P2) Series Hybrid QAM/IP HD Set-top Terminal • Installation Manual

41

574702-001 a

This document is uncontrolled pending incorporation in a Motorola CMS

Page 49
Image 49
Motorola QIP7000 installation manual Diagnostics, Field, Description, Front Panel, 574702-001 a