Motorola QIP7000 installation manual Diagnostics, Field, Description, 574702-001 a

Models: QIP7000

1 86
Download 86 pages 50.12 Kb
Page 77
Image 77
Manual background

Diagnostics

B

Field

Description

 

 

 

 

 

 

 

 

connection to MAC PID Stream.

 

 

 

 

 

I dc

INIT_WAIT_DC_OR_C

The QIP7000 series is in the interactive

 

 

 

initialization state and waiting for the

 

 

 

default configuration or the contention

 

 

 

channel list messages.

 

 

 

 

 

I L

WAIT_LM_ACK

The QIP7000 series is in the interactive

 

 

 

initialization state and waiting for Link

 

 

 

Management Response ACK for Local

 

 

 

Address Message.

 

 

 

 

 

I SO

WAIT_SO_ACK

The QIP7000 series is in the interactive

 

 

 

initialization state and waiting for a Sign On

 

 

 

acknowledgement.

 

 

 

 

 

I LA

WAIT_LA_OR_SO

The QIP7000 series is in the interactive

 

 

 

initialization state and waiting for Logical

 

 

 

Address or Sign On with verification

 

 

 

Frequency message.

 

 

 

 

 

S I

INIT_STOPPED

The QIP7000 series is in the interactive

 

 

 

initialization state and the TransMode has

 

 

 

stopped.

 

 

 

 

 

r dc

RUN_WAIT_DC_OR_C

The QIP7000 series is in the interactive

 

 

 

state and waiting for the default

 

 

 

configuration or the contention channel list

 

 

 

messages.

 

 

 

 

 

r

RUNNING

Interactive state is running, sending idle

 

 

 

messages, and waiting for any prepare for

 

 

 

poll or MAC messages.

 

 

 

 

 

S

RUN_STOPPED

The interactive run state has stopped and

 

 

 

the QIP7000 series is waiting for status or

 

 

 

a transmission control message.

 

 

 

 

 

00

INVALID

The interactive state is unknown or invalid.

 

 

MAC Abort Cntr

This counter increments every time the MAC layer reaches the cell abort count

 

limit. It is reset when the QIP7000 series receives an ACK. If the counter

 

reaches the MAC abort count limit, the QIP7000 series assumes the MAC layer

 

is unavailable due to noise, congestion, or some other problem. The QIP7000

 

series stops transmitting data, reports an error to the calling function, and

 

attempts to re-enter the network using the initialization process. 0000 is

 

displayed as the default or if the MAC Abort CNTR is not configured or

 

unknown.

 

 

 

 

 

Socket Port

The socket mode and activity:

 

State

UNUSED — The socket is not being used.

OPENED — The socket is open.

READY — The socket is ready to send or receive.

RECEIVING — The socket is receiving data from the application server.

SENDING — The socket is sending data to the application server.

UNKNOWN — The socket state is invalid or unknown.

QIP7000 (P2) Series Hybrid QAM/IP HD Set-top Terminal • Installation Manual