MAINTENANCE PROCEDURE

“13-C”: CCH C-Level Infinite Loop Failure (Temporary)

(1)Meaning

The system message “13-C” indicates that C-level infinite loop for PM (Port Microprocessor) within a CCH/ CCT circuit card has occurred less than 16 times within an hour. When the number of the fault occurrence time is less than 8, the Phase 1 restart is executed.

If the number of fault occurrence time is 8 to 16, the Phase 3 restart is executed.

(2)Related System Message

When the C-level infinite loop failure occurs more than 15 times, the specific PM of CCH/CCT is placed into make-busy state and the system message “13-B” is output.

(3)Example of Printout

SYSTEM MESSAGE 13-C [SUP]

CCH C-LEVEL INFINITE LOOP FAILURE (TEMPORARY)

NEC TOKYO

 

MAY 14 10:30

 

LP00-0-ACT

 

 

 

1: XX00 0000 0000 0000

2: 0000 0000 0000 0000

3: 0000 0000 0000 0000

(a)

5: 0000 0000 0000 0000

6: 0000 0000 0000 0000

4: 0000 0000 0000 0000

7: 0000 0000 0000 0000

8: 0000 0000 0000 0000

9: 0000 0000 0000 0000

 

 

 

 

(4)Message Detail Data

(a)Accommodated location of the CCH detected the fault. (Refer to paragraph 2.2.1)

MG

U

G

MG: Module Group

U:Unit

G:Group

CHAPTER 8

ND-71762 (E)

Page 94

Issue 2

Page 108
Image 108