MAINTENANCE PROCEDURE

3.3 Fault Repair Procedure for Digital CCIS Line

START

Check the connectors and flat cables between DTI and CCH.

 

 

 

 

 

Check the connector

 

 

 

 

 

On the DTI card, set the MBR switch UP . On the CCH card,

 

 

 

 

 

 

 

 

 

set the SW01-0, 1 UP .

 

 

 

 

 

 

 

 

 

 

 

On the DTI/CCH card, set the MB switches UP .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check whether the connector is correctly connected or not for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

both cards. If the connection is found an improper connection, plug and

 

 

 

 

 

 

 

 

 

unplug the connector for a few times.

 

 

 

 

 

 

 

 

 

 

 

On the DTI and CCH cards, set the MB and MBR switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN .

 

 

 

 

 

 

 

 

 

 

 

Check whether the fault is still indicated or not.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the flat cable

 

 

 

 

 

On the DTI card, set the MBR switch UP . On the CCH card,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set the SW01-0, 1 UP .

 

 

 

 

 

 

 

 

 

 

 

On the DTI and CCH card, set the MB switches

UP .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test the continuity of the flat cable. If found abnormal,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace the flat cable with spare.

 

 

 

 

 

 

 

 

 

 

 

On the DTI and CCH cards, set the MB and MBR switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN .

 

 

 

 

 

 

 

 

 

 

 

Check whether the fault is still indicated or not.

 

 

 

 

 

 

 

 

 

 

 

Check by replacing the DTI card

 

 

 

 

On the DTI card, set the MBR switch UP and then MB switch

 

 

 

 

with spare

 

 

UP .

 

 

 

 

 

 

 

 

 

 

 

Extract the card from the mounting slot.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On a new DTI card, make switch setting referring to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

extracted card.

 

 

 

 

 

 

 

 

 

 

 

On the new DTI card, set the MBR switch

UP .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On the new DTI card, set the MB switch

UP and insert the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card into the mounting slot.

 

 

 

 

 

 

 

 

 

 

 

On the new DTI card, set the MBR and MB switches DOWN .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check whether the fault is still indicated or not.

 

 

 

 

 

 

 

 

 

 

 

Check by replacing the CCH/CCT

 

 

 

On the CCH/CCT card, set the MBR switch UP.

 

 

 

 

 

card with spare

 

 

Note : MBR switch s name varies depending on the card.

 

 

 

 

 

 

 

 

 

On the CCH/CCT card, set the MB switch UP and extract the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card from its mounting slot.

 

 

 

 

 

 

 

 

 

 

 

Make switch setting on the new CCH/CCT card, referring to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the card extracted.

 

 

 

 

 

 

 

 

 

 

 

On the new CCH/CCT card, set the MBR and MB switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP and insert the card into its mounting slot.

 

 

 

 

 

 

 

 

 

 

On the new CCH/CCT card, set the MB switch

DOWN .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On the new CCH/CCT card, set the MBR switch

DOWN .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check whether the fault is still indicated.

 

 

 

 

 

 

 

 

 

 

 

 

 

END

ND-71762 (E)CHAPTER 8

Page 115

Issue 2

Page 129
Image 129
NEC ND-71762(E) system manual Fault Repair Procedure for Digital Ccis Line, Start