MAINTENANCE PROCEDURE
4. CCIS LINE OPERATING MODE CONTROL
This Section describes the Make Busy/Make Busy Cancel procedure and the Reinitialization procedure for CCH cir- cuit.
CCIS Line Operating Mode Control
Make Busy/Make Busy Cancel of CCH
Reinitialization of CCH
Circuit Card
Command CCSE
: Make Busy/Make Busy Cancel for a CCH circuit (not including speech path cannels).
MBR
switch : Make Busy/Make Busy Cancel for a CCH circuit (not including speech path cannels).
MB
switch : Make Busy/Make Busy Cancel for a CCH/ CCT circuit card.
Note : The MBR switchs name varies depending on the card.
MBR Switch operation on CCH circuit card.
Set the MB switch UP
and confirm that the OPE lamp goes out.
About 3 seconds later, set the MB switch DOWN
and confirm that the OPE lamp illuminates.
CHAPTER 8 |
|
Page 118
Issue 2