ND-71762 (E) CHAPTER 4
Page 33
Issue 2
INSTALLATION PROCEDURE
3.2 Setting of Switch Positions and Mounting of the Circuit Cards
The setting of switch positions and mounting of circuit cards should be performed according to the flowchart below.
START
Unpack the circuit cards. Unpack each circuit card and remove it from the
polyethylene bag.
Clean the connector portion of the
circuit cards.
Wipe the connector portion clean using a soft cloth
moistened with pure trichloroethylene or methanol
(medical alcohol). Make sure that no lint or dust
remains on the connector after cleaning.
Circuit cards which are already mounted should be
extracted and cleaned as per the above instructions.
Confirm the mounting positions of the
circuit cards.
Confirm the mounting position of each circuit card by
referring to the Module Face Layout of the Circuit Card
Manual.
Confirm that the color code of the card puller tab
coincides with that of the card mounting slot.
Confirm the slot number on the module. Slot numbers
are indicated at the top of each module, and range from
00 to 23.
Perform switch setting. Set the required switches according to the Switch
Setting Sheets in CHAPTER 3.
Mount the circuit cards. After the switches have been set, insert the card in the
module. Refer to Figure 4-4.