MAINTENANCE PROCEDURE

3. CCIS (Common Channel Interoffice Signaling) Line Fault

This paragraph explains the fault repair procedure when any of the faults shown in Table 8-1 occur to a specific CCIS line.

3.1 Check Point

When repairing a CCIS Line fault, consider the following:

(1)Check alarm lamps on the CCH or CCT circuit card

(2)By referring to Figure 8-5, check the cable connection.

3.2 CCIS Line Control

The CCH within the CCH/CCT circuit card controls the signal link of the interoffice common channel signaling sys- tem and transmits/receives call processing information.

The signal link controls to send/receive the call processing information.

The call processing information is converted into No. 7 signal format for channel 1 (any channel) of the DTI before being transmitted to a distant office.

Figure 8-5 Controlling the CCIS Line

MUX

CPU

TSW

MDF

LT Cable

DTI

FRONT

CABLE

CCH

CCH MODEM MODEM CABLE

CCT

LT Cable MDF

To CCIS Line

CHAPTER 8

ND-71762 (E)

Page 114

Issue 2

Page 128
Image 128
NEC ND-71762(E) system manual Ccis Common Channel Interoffice Signaling Line Fault, Check Point, Ccis Line Control