MAINTENANCE PROCEDURE

“13-F”: CCH B-Level Infinite Loop Failure (Permanent)

(1)Meaning

The system message “13-F” indicates that B-level infinite loop (Note) of the PM (Port Microprocessor) within the CCH/CCT circuit card has occurred more than 15 times within an hour. When this fault has occurred, the specific PM is placed into make-busy state and restarted. (The fault counter is reset to “0” at every hour.)

Note: This is such a state in which the C-Level Monitor Program (the program which detects off-hook/on-hook related to lines/trunks) repeats a specific routine. The number of repeated times is counted by the error counter corresponding to the CPU.

(2)Related System Message

When the B-level infinite loop failure occurs less than 16 times, the Phase 1 restart or Phase 3 restart is exe- cuted at the specific PM and the system message “13-G” is output.

(3)Example of Printout

SYSTEM MESSAGE 13-F [SUP]

CCH B-LEVEL INFINITE LOOP FAILURE (PERMANENT)

NEC TOKYO

 

MAY 14 10:30

 

LP00-0-ACT

 

 

 

1: XX00 0000 0000 0000

2: 0000 0000 0000 0000

3: 0000 0000 0000 0000

(a)

5: 0000 0000 0000 0000

6: 0000 0000 0000 0000

4: 0000 0000 0000 0000

7: 0000 0000 0000 0000

8: 0000 0000 0000 0000

9: 0000 0000 0000 0000

 

 

 

 

(4)Message Detail Data

(a)Accommodated location of the CCH detected the fault. (Refer to paragraph 2.2.1)

MG

U

G

MG: Module Group

U:Unit

G:Group