6-5-3 Setup Tab

The CPU Bus Unit System Setup, which is set when using socket services, is shown in the CX-Programmer's Unit Setup Window.

.

Setup

Item

 

Details

 

 

Default value

 

 

 

Broadcast

Set the method for specifying IP address

All 1 (4.3BSD)

 

when broadcasting with FINS/UDP.

 

 

 

All 1 (4.3BSD): Broadcast

with

host

 

 

 

number set to all ones.

 

 

 

 

All 0 (4.2BSD): Broadcast

with

host

 

 

 

number set to all zeros.

 

 

 

 

For normal operations use the default:

 

 

All 1 (4.3BSD)

 

 

 

 

 

 

IP Address

Set local IP address for Ethernet Unit.

0.0.0.0 (Uses

 

 

 

 

 

192.168.250.FINS

 

 

 

 

 

node address)

 

 

 

Sub-net Mask

Set the subnet mask of the Ethernet Unit.

0.0.0.0

 

This setting is required when the IP

 

(Uses default net-

 

Address Table method is not used for IP

mask of IP

 

address conversion.

 

 

address setting.)

 

 

 

 

 

 

108