Example Application |
|
| Section | |
|
|
|
|
|
|
| Item name | Example | |
|
|
|
|
|
| Receive Command |
| Receive specified commands | Selected |
| Setting |
| only |
|
|
|
|
|
|
|
|
| FileWrite | Not selected |
|
|
|
|
|
|
|
| FileRead | Selected |
|
|
|
|
|
|
|
| FileDelete | Not selected |
|
|
|
|
|
|
|
| FileList | Selected |
|
|
|
|
|
|
|
| UMBackup | Selected |
|
|
|
|
|
|
|
| PARAMBackup | Selected |
|
|
|
|
|
|
|
| IOMWrite | Not selected |
|
|
|
|
|
|
|
| IOMRead | Selected |
|
|
|
|
|
|
|
| ChangeMode | Not selected |
|
|
|
|
|
|
|
| ErrorLogRead | Selected |
|
|
|
|
|
|
|
| ErrorLogClear | Selected |
|
|
|
|
|
|
|
| MailLogRead | Selected |
|
|
|
|
|
|
|
| MailLogClear | Selected |
|
|
|
|
|
|
|
| Test | Selected |
|
|
|
|
|
|
|
| FinsSend | Not selected |
|
|
|
|
|
3-9-3 Step 3. Transfer the CPU Bus Unit Setup Settings
Select Transfer to PLC from the Options Menu and click the Yes Button. The settings will be transferred to the CPU Bus Unit Setup Area in the CPU Unit.
3-9-4 Step 4. Send Remote Mail Commands
Send
Reading Data from a CPU Unit Data Area
Example)
In this example, 10 words of data are read from words D00100 to D00109 and converted to a file called D00100.CSV.
Subject: IOMRead
Body: Para1:38
Para2:D_100
Para3:10
Para4: D00100.CSV
Attached file:
None
Backing Up the CPU
Unit's User Program
in the Memory Card
Example)
In this example, the CPU Unit's user program is backed up in a file called USER.OBJ.
Subject:
UMBackup
Body:
Para2:USER.OBJ
Attached file:
None
66