Using FTP CommandsSection 4-5

4-5-3

Error Messages and FTP Status

Error Messages

 

 

The error messages returned by the Ethernet Unit are listed in the following

 

table.

 

 

 

 

 

Message

Meaning

 

 

PPP is a directory.

The path name indicated at PPP is a directory.

 

 

PPP is not a directory.

The path name indicated at PPP is not a directory.

 

 

Another unit has access authority

Another Unit currently has the access right.

(FINS error 0 x 3001).

 

 

 

Bad sequence of commands.

The RNFR command has not been executed.

 

 

Can't create data socket (X.X.X.X, YY).

A socket cannot be created.

 

 

Cannot access to device (FINS error 0 x 250F).

A file device error has occurred.

 

 

Cannot get memory blocks.

A message memory block cannot be allocated.

 

 

Command format error (FINS error 0 x 1003).

The command format is incorrect.

 

 

Connect error.

A connection error has occurred.

 

 

Directories of old and new paths are not same.

The directories before and after changing the name are different.

 

 

Directory name length exceeded max. size.

The directory name is too long.

 

 

Directory not empty (FINS error 0 x 2108).

The directory must be empty to delete it.

 

 

Fatal error (FINS error 0 x 1101).

A parameter error has occurred.

 

 

Fatal error (FINS error 0 x 1103).

 

 

 

File or directory already exists.

The specified file or directory name already exists.

 

 

File or directory already exists

 

(FINS error 0 x 2107).

 

 

 

File or directory name illegal.

The file or directory name is incorrect.

 

 

File or directory name illegal

 

(FINS error 0 x 110C).

 

 

 

File read error (FINS error 0 x 1104).

An error occurs when reading the file.

 

 

File read error (FINS error 0 x 110B).

 

 

 

File write error (FINS error 0 x 2106).

An error occurs when reading the file.

 

 

File write error (FINS error 0 x 2107).

 

 

 

FINS error MRES 0 x XX: SRES 0 x XX.

Some other FINS error has occurred.

 

 

Length of directory name too long.

The path name of the directory is too long.

 

 

No space to create entry (FINS error 0 x 2103).

There are too many files to create a new one.

 

 

No such device (FINS error 0 x 2301).

The file device cannot be found.

 

 

No such file or directory.

The specified file or directory does not exist.

 

 

No such file or directory (FINS error 0 x 2006).

 

 

 

No such file or directory (FINS error 0 x 2106).

 

 

 

Not enough memory.

The communications buffers are full.

 

 

Not enough space in the system.

The file device is full.

(FINS error 1104).

 

 

 

PLC communication error (timeout).

File access timed out.

 

 

Socket canceled.

The socket was canceled.

 

 

Socket error NN.

A socket bind error occurred. The error code will be given at NN.

 

 

Socket receive error NN.

A data reception error occurred. The error code will be given at NN.

 

 

Socket send error NN.

A data send error occurred. The error code will be given at NN.

 

 

Timeout (900 seconds): closing control connection.

The connection was closed because the client did not respond for 15

 

 

minutes.

 

 

Too many open files.

Too many sockets have been created.

 

 

Write access denied.

Writing is not possible.

 

 

Write access denied. (FINS error 0 x 2101).

 

 

 

 

78

Page 102
Image 102
Omron CJ1W-ETN21 operation manual Error Messages and FTP Status, Message Meaning