CHAPTER 4: Troubleshooting

Memory

Symptom / Error

Action in Sequence

 

 

 

Memory count (size) appears different from

Run “Load Setup Defaults” using the BIOS Setup Utility, then reboot

actual size.

 

the notebook.

 

Test or replace the SO-DIMM.

 

Test or replace the system board.

 

 

 

Sound

Symptom / Error

Action in Sequence

 

 

 

No sound comes from the notebook when

Reinstall the audio driver.

running Windows multimedia programs.

Test or replace the speakers.

 

Test or replace the system board.

 

 

 

The internal speakers make noise or emit no sound.

Test or replace the speakers.

Test or replace the system board.

Power management

Symptom / Error

Action in Sequence

 

 

The notebook will not hibernate.

Test or replace the keyboard (if control is from the keyboard).

Test or replace the hard disk drive.

Test or replace the system board.

The system doesn't hibernate and emits four short beeps every minute.

Press Fn+o and see if the notebook enters hibernation mode.

Test or replace the touchpad.

Test or replace the keyboard.

Check the hard disk connection to the system board.

Test or replace the hard disk drive.

Test or replace the system board.

The notebook doesn’t enter standby mode after

Make sure that the magnet is in the magnet holder. For more

closing the LCD.

 

information, see “Replacing the LCD panel” on page 84.

 

Test or replace the system board.

 

 

 

The system doesn't resume from hibernation mode.

Check the hard disk connection to the system board.

Test or replace the hard disk drive.

Test or replace the system board.

The system doesn't resume from standby mode

Make sure that the magnet is in the magnet holder. For more

after opening the LCD.

 

information, see “Replacing the LCD panel” on page 84.

 

Test or replace the system board.

 

 

 

The battery fuel gauge in Windows doesn’t go higher than 90%.

Remove the battery pack and let it cool for two hours.

Refresh the battery (use only battery power until the notebook turns off, then charge the battery).

Test or replace the battery pack.

Test or replace the system board.

The system hangs intermittently.

Reconnect the hard disk drive and optical drive.

 

Check the hard disk connection to the system board.

 

Test or replace the system board.

 

 

 

112