All Reset

When the all reset mode is activated, all of the following set- tings will be reset to the factory default.

Administrator password

PS·Data communication setting

LCD brightness, contrast, alarm buzzer, and button buzzer settings

Button functions and joystick button functions (F1 to F8, A, B, and top buttons)

Controller functions

(Time & Date Type)

(Auto Login)

(Operator Setup)

(Function Level)

(Camera Level)

(Cam Posi Map)

(Cam-Unit Map)

(HDD-Unit Map)

(LCD Title)

Note: Calibration settings of panning, tilting, and zooming will be maintained even after all reset.

Operation

1.Turn off the power.

Note: If you set the MODE Switch #1 to #4 to ON, you can skip entering the administrator password in Step 3.

2.Turn on the power while holding down the buttons 2, 4, and 6.

“Admin Password” will appear on the LCD to enter the password.

All Reset

Admin Password _____

3.Enter the administrator password.

The password entered will be displayed as “” marks.

All Reset

Admin Password ∗ ∗ ∗ ∗ ∗

Notes:

The factory default is “650”.

To delete a character, press the CLEAR button.

If you have entered a wrong password, the LCD display will return to Step 2.

4.Press the CAM (SET) button.

If the password entered is correct, all the settings will be reset to the factory default.

All Reset

5.Check “End” on the LCD.

Check “End” has appeared on the LCD to inform you of the initialization end.

All Reset

End

6. Turn off the power.

PS·Data Communication Setting

This setting is required to establish a connection between the system units and system controller.

List of PS·Data communication settings

Setting Item Available setting parameter(s)

Baud Rate

4800 / 9600 / 19200 bps

Data Bit

8 bit (Fixed)

Parity Bit

None / Odd / Even

Stop Bit

1 / 2 bit

Wait Time

OFF / 100 msec / 200 msec /

 

400 msec / 1000 msec

 

 

Group Adr

A to Z

Xon/Xoff

Not Use (Fixed)

Note: Factory defaults are underlined.

Operation

1.Turn off the power.

2.Turn on the power while holding down the button 6 and MON (ESC) button.

“Admin Password” will appear on the LCD to enter the password.

PS Data Com. Setup

Admin Password _____

20

Page 20
Image 20