3.Enter the administrator password.

The password entered will be displayed as “” marks.

PS Data Com. Setup

Admin Password ∗ ∗ ∗ ∗ ∗

Notes:

The factory default is “650”.

To delete a character, press the CLEAR button.

4.Press the CAM (SET) button.

If the password entered is correct, "Baud Rate" setting form will appear on the LCD.

PS Data Com. Setup

Baud Rate 9600

Notes:

If the password entered is wrong, “PS·Data Com. Setup” will appear on the LCD again to reenter the password.

You can change the setting item display on the LCD by rotating the JogDial.

5.Select an item you wish to set up by rotating the JogDial.

Baud rate

PS Data Com. Setup

Baud Rate 9600

The speed of communication between the system controller and other system units

Parity bit

PS Data Com. Setup

Parity Bit None

The parity bit, added to the data, to perform parity check (Refer to p. 22 for details.)

Stop bit

PS Data Com. Setup

Stop Bit 1

The stop bit, added to the last of data, in asynchronous communication (Refer to p. 22 for details.)

Wait time

PS Data Com. Setup

Wait Time Off

The wait time until the data is sent again (Refer to p. 22 for details.)

Controller group address

PS Data Com. Setup

Cnt G—Adr. A

(No need for setup) Remain the factory default.

System unit group address

PS Data Com. Setup

Sys G—Adr.

(No need for setup) Remain the factory default.

6.Perform the settings.

Setting procedures differ depends on items. Refer to p. 21 to 23 for how to operate.

7.After you have completed the settings, turn off the power.

Baud Rate Setting

1.Select “Baud Rate” by rotating the JogDial. (Refer to Step 5 in Operation.)

2.Press the CAM (SET) button.

The LCD display will change from the display mode to the editing mode.

PS Data Com. Setup

Baud Rate 9600

3.Select a desired parameter by rotating the JogDial, or pressing the + or – button.

You can select the desired parameter from “19200”, “9600”, and “4800”. The factory default is “9600”.

PS Data Com. Setup

Baud Rate 4800

Note: Conform this parameter to the baud rate of other sys- tem units. Otherwise, communication will not be estab- lished between the system controller and system units.

21

Page 21
Image 21
Panasonic WV-CU650 operating instructions Baud Rate Setting