Using the Command Line Interface (CLI)

Link Integrity Parameters

 

Name

Type

Values

Access

CLI Parameter

 

Link Integrity

Group

N/A

R

linkint

 

Link Integrity Status

Integer

enable

RW

linkintstatus

 

 

 

disable (default)

 

 

 

Link Integrity Poll

Integer

500 - 15000 ms

RW

linkintpollint

 

Interval

 

(in increments of 500ms)

 

 

 

 

 

500 ms (default)

 

 

 

Link Integrity Poll

Integer

0 - 255

RW

linkintpollretx

 

Retransmissions

 

5 (default)

 

 

Link Integrity IP Target Table

 

 

 

Name

Type

Values

Access

CLI Parameter

Link Integrity IP Target

Table

N/A

R

linkinttbl

Table

 

 

 

 

Table Index

Integer

1-5

N/A

index

Target IP Address

IpAddress

User Defined

RW

ipaddr

Comment (optional)

DisplayString

User Defined (up to 254

RW

cmt

 

 

characters)

 

 

Status (optional)

Integer

enable

RW

status

 

 

disable (default)

 

 

 

 