When Nozzle Clogging Cannot Be Solved

5

Open the left maintenance cover.

Rotate it left.

Screw

(1) Turn four screws that fix the maintenance cover to

 

 

 

 

the left, and remove them.

 

 

 

(2) Remove the maintenance cover.

 

 

 

• If the maintenance cover is hard to remove, use the

Maintenance

 

 

supplied screwdriver.

cover

 

 

 

 

 

 

 

Screw

6

Immerse Wiper for CR in Maintenance kit.

 

Wiper for CR

• Immerse much enough so that washing

 

 

liquid may drip from it.

Do not wipe the nozzle surface with dry Wiper for CR.

7

Wipe the nozzle surface from the rear of the main

Nozzle surface

 

body to the front twice or three times with Wiper for CR immersed in Maintenance kit.

• Do not rub too strong.

• If Wiper for CR has fluffed, replace it.

• If ink solid adheres to Wiper for CR, change the surface to use for cleaning or replace it.

8

Press the

key after the cleaning.

C l o s e c o v e r

 

 

 

 

 

 

COMP L E T ED

[ ENT ]

 

 

 

 

 

9

Close the left maintenance cover then press the

 

 

 

 

 

key.

• After its initial operation, the machine returns to step1.

10

Perform head cleaning. (

P.2-22)

11

Perform test printing. (

P.2-20)

 

 

 