Chapter C
C - 34
7Remove the protective sheet from the
new OPC belt cartridge. Do not touch
the green part of the OPC belt cartridge.
8Put the new OPC belt cartridge into the
machine guides with the flat side facing
you.
9To lock the cartridge into the machi ne,
push the belt cartridge lock levers that
are on both sides of the OPC belt
cartridge outwards.
0Close the inside cover, and then clos e
the scanner unit.
ATurn the machine’s power switch back
on.
Reset the OPC belt life counter
1Press Menu/Set,7,4.
2Press or to select OPC Belt
and press Menu/Set.
The confirmation message appears on
the LCD.
3Press 1 to reset the life counter.
OR
Press 2 to cancel.
OPC Belt
1.Reset 2.Exit