SMC Networks SMC6224M manual Logging sendmail host, Syntax No logging sendmail host ipaddress

Models: SMC6224M

1 522
Download 522 pages 38 Kb
Page 315
Image 315

SYSTEM MANAGEMENT COMMANDS

Table 4-21 SMTP Alert Commands (Continued)

Command

Function

Mode

Page

logging sendmail

Enables SMTP event handling

GC

4-70

 

 

 

 

show logging

Displays SMTP event handler settings

NE,

4-70

sendmail

 

PE

 

 

 

 

 

logging sendmail host

This command specifies SMTP servers that will be sent alert messages. Use the no form to remove an SMTP server.

Syntax

[no] logging sendmail host ip_address

ip_address - IP address of an SMTP server that will be sent alert messages for event handling.

Default Setting

None

Command Mode

Global Configuration

Command Usage

You can specify up to three SMTP servers for event handing. However, you must enter a separate command to specify each server.

To send email alerts, the switch first opens a connection, sends all the email alerts waiting in the queue one by one, and finally closes the connection.

To open a connection, the switch first selects the server that successfully sent mail during the last connection, or the first server configured by this command. If it fails to send mail, the switch selects the next server in the list and tries to send mail again. If it still fails, the system will repeat the process at a periodic interval. (A trap will be triggered if the switch cannot successfully open a connection.)

4-67

Page 315
Image 315
SMC Networks SMC6224M manual Logging sendmail host, Syntax No logging sendmail host ipaddress