BASIC CONFIGURATION

CLI – Enter the IP address of at least one SMTP server, set the syslog severity level to trigger an email message, and specify the switch (source) and up to five recipient (destination) email addresses. Enable SMTP with the logging sendmail command to complete the configuration. Use the show logging sendmail command to display the current SMTP configuration.

Console(config)#logging sendmail host 192.168.1.200

4-67

Console(config)#logging sendmail level 4

4-68

Console(config)#logging sendmail source-email

 

john@acme.com

 

4-69

Console(config)##logging sendmail destination-email

 

geoff@acme.com

 

4-69

Console(config)#logging sendmail

4-70

Console(config)#exit

 

 

Console#show logging sendmail

4-70

SMTP

servers

 

 

-----------------------------------------------

 

1.

192.168.1.200

 

 

SMTP

minimum severity level: 4

 

SMTP

destination email addresses

 

-----------------------------------------------

 

1.

geoff@acme.com

 

 

SMTP

source email address:

john@acme.com

 

SMTP

status:

Enabled

 

Console#

Resetting the System

Web – Click System, Reset to reboot the switch. When prompted, confirm that you want reset the switch.

Figure 3-19 Resetting the System

3-41

Page 95
Image 95
SMC Networks SMC6224M manual Resetting the System