B

ASIC

C
ONFIGURATION
3-13

CLI – Specify the hostname, location and contact information.

Displaying Switch Hardware/Software Versions

Use the Switch Information page to display hardware/firmware version

numbers for the main board and management software, as well as the

power status of the system.

Field Attributes

Main Board

Serial Number – The serial number of the switch.

Number of Ports – Number of built-in RJ-45 ports.

Hardware Version – Hardware version of the main board.

Console(config)#hostname R&D 5 4-34
Console(config)#snmp-server location WC 9 4-137
Console(config)#snmp-server contact Ted 4-136
Console(config)#exit
Console#show system 4-82
System description: 24-Port 10/100Mbps Stackable Managed Switch
with 2 optional uplink modules
System OID string: 1.3.6.1.4.1.202.20.43
System information
System Up time: 0 days, 2 hours, 4 minutes, and 7.13
seconds
System Name: R&D 5
System Location: WC 9
System Contact Ted
MAC address 00-30-F1-12-34-56
Web server: enabled
Web server port: 80
Web secure server: enabled
Web secure server port: 443
Telnet server: enabled
Telnet port: 23
Jumbo Frame: Disabled
POST result
DUMMY Test 1.................PASS
UART LOOP BACK Test..........PASS
DRAM Test....................PASS
Timer Test...................PASS
RTC Initialization...........PASS
Switch Int Loopback test.....PASS
Done All Pass.
Console#