STEPLIB: Enter the names of the DB2 Manager and Archive Manager product load libraries.

OTASxxxx: Enter the name of the primary index dataset of the Archive Manager database used for storage of objects from the DB2 table being processed by the utility. ‘xxxx’ should be set to the 4-character value used to identify the Archive Manager database in the DB2 Manager control region procedure (see “Perform MVS host system modifications” on page 21).

SYSPRINT: This entry is used for all print reports created during utility execution.

SYSIN: This is a sequential dataset or in-stream JCL file containing fixed-length 80 byte records, and is used for specification of the parameters used to control utility execution. Refer to “SYSIN parameter specification” on page 101 for a description of how to specify parameter entries in this file.

SQLIN: This is a sequential dataset or in-stream JCL file containing fixed-length 80 bytes records, and is used for specification of the criteria to be used by the utility for pre-fetching of rows by Archive Manager. Refer to “SQLIN entry specification” on page 102 for a description of how to specify a pre-fetch criteria entry in this file.

SYSIN parameter specification

Parameters used to control execution of the utility are specified in file SYSIN. This must be a sequential dataset or in-stream JCL file containing one or more fixed-length 80-byte records, each record containing one or more separate parameter entries. Each parameter entry must be completely contained within one record (ie) continuation of any single parameter entry from one record to another is not permitted. A single record may contain multiple parameter entries, each being separated by one or more spaces, and optionally a single comma (‘,’).

A parameter entry has the general format:

keyword = value

Each keyword and its associated value are separated by an '=' sign, and optionally one or more spaces. The first keyword parameter in a record may begin in any character position from 1 onwards. Parameters may extend up to character position 71 of the record. Individual keyword parameters may not be continued over more than one record.

An asterisk ('*') in character position 1 will indicate a comment record, which will be ignored for parameter validation processing.

The following parameters may be specified:

DB2SSID=xxxx

DB2 Manager User Guide