StorageTek 312564001 manual OTD10015 The control region is not active

Models: 312564001

1 189
Download 189 pages 56.09 Kb
Page 125
Image 125

OTD10013 Return code ‘xx’ received during execution of TCBTOKEN LOCASCB ENQ macro.

Explanation: An error has been received attempting to execute the system macro identified in the message. ‘xx’ is the return code received from the macro call. Execution of the utility is terminated with condition code 12.

Action: Consult IBM system macro documentation for a description of the error. Take the appropriate corrective action and re-submit the job. If no obvious cause for the error can be determined, contact your local STK support representative.

OTD10014 Error X'xxxx’ Info X'yyyy’ dynamically allocating DDname OTDBS100

Explanation: An error has been received attempting to dynamically allocate temporary file OTDBS100. ‘xxxx’ and ‘yyyy’ give the hexadecimal error and information codes returned from the dynamic allocation request. Execution of the utility is terminated with condition code 12.

Action: Refer to IBM documentation on dynamic allocation (SVC99) processing for a description of the error and information codes displayed in the message. Take the appropriate corrective action and re-submit the job. If no obvious cause for the error can be determined, contact your local STK support representative.

OTD10015 The control region is not active

Explanation: An attempt has been made to run the row migration utility while the DB2 Manager is not started. Execution of the utility cannot continue.

Action: Ensure that the DB2 Manager control region is started before attempting to run the utility.

OTD10016 Normal run requested but restart run required

Explanation: RESTART=NO has been specified or defaulted in the SYSIN execution parameters specified for the jobstep, but the previous attempt to migrate rows to the Archive Manager database specified in the LCDDBID execution parameter failed. Execution of the utility is terminated with condition code 12.

Action: Check that the LCDDBID execution parameter has been specified correctly. If it has, RESTART=YES must be specified in the SYSIN parameters. Correct the SYSIN parameters as required, and re- submit the job.

OTD10017 Unable to obtain ODRE request element