Explanation: ‘COMMAND=MODIFY’ is set in the Archive Manager/OAM TAPECNTL parameter library member, but an MVS command other than ‘MODIFY’ has been issued to the DB2 Manager control region.

Action: Re-enter the DB2 Manager command using the standard MVS MODIFY command structure. Refer to “DB2 Manager operator interface” on page 50 for more information on entering DB2 Manager control region commands.

OTD20033 I/O error X'xxxx' processing ENVCNTL TAPECNTL parameter member

Explanation: An I/O error has occurred processing the identified member from the DB2 Manager parameter library during control region initialization processing. 'xxxx' gives the first two sense bytes from the IOB at the time of the error. Control region initialization is aborted.

Action: Refer to IBM documentation for a description of the error code. Take the appropriate corrective action and restart the control region.

If no apparent cause for the error can be detected, contact your DB2 Manager product support representative.

OTD20034 Error X’xx’ received loading program XXXXXXXX

Explanation: An error has occurred dynamically loading the program identified in the message. ‘xx’ gives the hexadecimal error record received from the LOAD request.

Action: Refer to IBM macro documentation for a description of the error code in the message. Ensure that the program identified in the message is available to be loaded from the steplib, joblib or linklist concatenation. Consult other available system messages for additional information on the load error. Take the appropriate corrective action and restart the control region.

OTD20049 Task tnnn shutdown request has failed - error X'xx'

Explanation: Shutdown of a sub-task has failed during control region termination processing. ‘xx’ gives the hexadecimal return code from the DETACH macro. ‘t’ identifies the sub-task type (‘D’ – disk reader; ‘H’ – housekeeping; ‘S’ – scheduler; ‘T’ – tape reader; ‘W’ – writer) and ‘nnn’ gives the sub-task number. Termination of the control region continues.

Action: None. This is an informational message. System abend ‘A03’ may be received on termination of the control region after display of this message.

OTD20050 Missing or invalid request - ignored