If set to 0 (the default), no internal queuing of requests will take place in the above circumstances and the request will be rejected with a ‘resource unavailable’ reason code.

If the TAPEWAIT parameter value is in the range 1-1439, requests will be queued internally until processed or until the maximum queuing time in minutes (as specified in this parameter) has been exceeded. Requests will then be rejected with a ‘resource unavailable’ reason code (as above).

If the TAPEWAIT parameter value is 1440, then requests will be held indefinitely in the internal queue until the necessary resources to process the request become available.

Notes: This setting may be varied during DB2 Manager operation via the 'SET TAPEWAIT’ operator command.

If this parameter is omitted, a default value of TAPEWAIT=0 will be used.

TAPECNTL: COMMAND

COMMAND = REPLYMODIFY

Requirement: Optional

Default: COMMAND=REPLY

Validation: The parameter values REPLY or MODIFY must be specified.

Use: This is an optional parameter which is used to control the method by which operator commands are passed to the DB2 Manager control region. The default value of ‘REPLY’ will cause the control region to output the operator reply message OTD20000 when it is ready to receive an operator command.

If ‘MODIFY’ is specified, no operator reply message will be displayed. Operator commands must be entered via an MVS MODIFY command

(eg) F LCDDB2,SET MAXTRDR=2

The value of this setting cannot be modified during control region operation

42

DB2 Manager User Guide

 

StorageTek Proprietary

Page 45
Image 45
StorageTek 312564001 manual Tapecntl Command