StorageTek 312564001 manual DB2 Manager User Guide

Models: 312564001

1 189
Download 189 pages 56.09 Kb
Page 123
Image 123

OTD10006 DB2 CAF error occurred during CONNECT OPEN CLOSE DISCONNECT processing. Return Code = xxx, Reason Code = X'yyyyyyyy’

Explanation: A DB2 Call Attachment Facility error has occurred attempting to perform the type of processing identified in the message. ‘xxx’ gives the return code and ‘yyyyyyyy’ the hexadecimal reason code returned by the Call Attachment Facility. Execution of the utility is terminated with condition code 12.

Action: Refer to the DB2 Application Programming and SQL Guide for a description of CAF error and reason codes. Take the appropriate corrective action and re-start the utility.

OTD10007 The LCDDBID specified in the exec parameters is not consistent with the DB2 table name specified in the SQLIN statements

Explanation: The Archive Manager database identifier specified in the SYSIN execution parameters does not match that used previously for migration of rows from the DB2 table specified in the SQLIN file. Execution of the utility is terminated with condition code 12.

Action: Check that the correct values have been specified for the LCDDBID parameter in the SYSIN parameters, and the table name specified in the SQLIN file. Correct the invalid entry and re-submit the job.

If no error can be found in the parameter specifications, check the row entry in the LCDDB2.REGISTRY table for the table specified in the SYSIN parameters. The LCDDBID column in this row contains the Archive Manager database identifier associated with this table. The DB2 Manager row migration utility may only be executed if this combination of DB2 table and Archive Manager database identifier is specified in the parameters used to execute the utility. Ensure that the parameters supplied to the utility are consistent with the entry in the LCDDB2.REGISTRY table.

OTD10008 DB2 Table contains Large Objects (LOBs) or 'distinct types'

Explanation: The DB2 table specified in the SQLIN file cannot be processed, because it contains large objects (LOBs) or ‘distinct types’. Tables containing these entities are not eligible for migration using DB2 Manager. Execution of the utility is terminated with a condition code 12.

Action: Check that the correct DB2 table name has been specified in the SQLIN file. If not, correct the entry and re-submit the job.

OTD10009 Key xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx was not found in DB2 table

120

DB2 Manager User Guide

 

StorageTek Proprietary

Page 123
Image 123
StorageTek 312564001 manual DB2 Manager User Guide