Explanation: All
Action: None. This is an informational message.
OTD20016 OTDBP300 is not in Link Pack Area
Explanation: The DB2 Manager row edit routine OTDBP300 was not found in the FLPA or MLPA during control region initialization processing. The control region is terminated.
Action: Ensure that module OTDBP300 is installed in the FLPA or MLPA before restarting the control region (see “Perform MVS host system modifications” on page21 for a discussion of this requirement).
OTD20017 Intercept successfully established
Explanation: The Archive Manager /DB2 row edit routine OTDBP300 has been located in the FLPA or MLPA, and has been successfully initialized.
Action: None. This is an informational message.
OTD20018 ENQueue Error: Major: mmmmmmmm Minor: nnnnnnnnnnnnnnnn Return code=X'xx'
Explanation: An error has been received attempting to enqueue on the resource whose major and minor names are identified in the message. ‘xx’ is the return code received from the ENQ macro.
Action: Refer to IBM documentation on ENQ macro processing for a description of the return code. Take the appropriate corrective action and
144 | DB2 Manager User Guide |
| StorageTek Proprietary |