If the value of MAXTWTR is to be increased, DB2 Manager

 

 

will increase the number of initialized writer tasks, by

 

 

restarting terminated tasks, and/or adding new tasks.

 

 

If the value of MAXTWTR is to be decreased, DB2

 

 

Manager will terminate a number of existing writer tasks

 

 

equal to the decrease in the value of MAXTWTR. These

 

 

tasks will appear with the status TERM in any subsequent

 

 

status display, and will not be available for object recall

 

 

processing.

 

 

Note that processing of this command may take a little

 

 

time for significant changes in the value of MAXTWTR.

 

MAXSCHED -

DB2 Manager will alter the current setting of the

 

 

MAXSCHED parameter to the value specified in the SET

 

 

command. The value ‘nnn’ must be a 1-3 digit numeric

 

 

value in the range 1-255.

 

 

If the value of MAXSCHED is to be increased, DB2

 

 

Manager will increase the number of initialized tape reader

 

 

tasks, by restarting terminated tasks, and/or adding new

 

 

tasks.

 

 

If the value of MAXSCHED is to be decreased, DB2

 

 

Manager will terminate a number of existing tasks equal to

 

 

the decrease in the value of MAXSCHED. These tasks will

 

 

appear with the status TERM in any subsequent status

 

 

display, and will not be available for object recall

 

 

processing.

 

 

Note that processing of this command may take a little

 

 

time for significant changes in the value of MAXSCHED.

 

MAXQLEN -

DB2 Manager will alter the current setting of the

 

 

MAXQLEN parameter to the value specified in the SET

 

 

command. ‘nnn’ must be a 1-3 digit numeric value in the

 

 

range 1-256.

 

RETAINTAPE -

DB2 Manager will alter the current setting of the

 

 

RETAINTAPE parameter to the value specified in the SET

 

 

command. ‘nnnn’ must be a 1-4 digit numeric value in the

 

 

range 0-1440.This change will take immediate effect.

 

TAPEWAIT -

DB2 Manager will alter the current setting of the

 

 

TAPEWAIT parameter to the value specified in the SET

 

 

command. ‘nnnn’ must be a 1-4 digit numeric value in the

 

 

range 0-1440. This change will take immediate effect.

 

OBJSIZE -

DB2 Manager will alter the current setting of the OBJSIZE

 

 

parameter to the value specified in the SET command.

 

 

‘nnnnn’ must be a 1-5 digit numeric value in the range 1-

60