Explanation: The column name identified in the message has been specified as a key field in the SQLIN file, but the column does not exist in the DB2 table. Execution of the utility is terminated with condition code 12.

Action: Check that the names of the columns which uniquely index each row in the table have been specified correctly in the SQLIN file, and re- submit the job.

OTD10010 SQL Error during execution of xxxxxxxx command SQLCODE = xxxx

Explanation: An error has been received executing the SQL command identified in the message. Processing of the utility is terminated with a condition code 12. All DB2 and Archive Manager updates performed by the utility will be rolled-back to the last commit point. The following SQL commands may appear in this message: DESCRIBE, PREPARE, DECLARE, SET, EXECUTE, OPEN, FETCH, CLOSE, COMMIT. The message will be followed by a line containing parameters from the appropriate SQL error message.

Action: Refer to the DB2 Messages and Codes manual for a description of the SQL error code displayed in the message. Take the appropriate corrective action and re-submit the job, with SYSIN parameter “RESTART=YES” specified.

OTD10011 Return code X'xx’ retrieving Name/Token pair

Explanation: An error has occurred retrieving an OS/390 name/token pair. ‘xx’ gives the hexadecimal reason code received from the retrieve request. Execution of the utility is terminated with condition code 12.

Action: Refer to IBM documentation on the IEANTRT callable service for a description of the error code. Take the appropriate corrective action and re-submit the job. If no obvious cause for the error can be identified, contact your local STK support representative.

OTD10012 Error locating ODCT

Explanation: The utility has been unable to locate the DB2 Manager control region communications table (ODCT) in ECSA storage. Execution of the utility is terminated with condition code 12.

Action: To resolve this error, terminate and re-start the DB2 Manager control region, then re-submit the job. If the error persists, contact your local STK support representative.