StorageTek 312564001 manual SQLIN entry specification, PLAN=xxxxxxxx

Models: 312564001

1 189
Download 189 pages 56.09 Kb
Page 105
Image 105

This mandatory parameter is used to specify the subsystem identifier of the DB2 subsystem to be used during execution of the utility. The subsystem identifier ‘xxxx’ can be 1-4 characters in length.

PLAN=xxxxxxxx

This is an optional parameter which is used to specify the DB2 plan name to be used during execution of the utility, where ‘xxxxxxxx’ is the 1-8 character identifier of the plan. If omitted, a default value of OTDBL130 is used. Refer to “Perform DB2 system modifications” on page 25 for information about DB2 Manager plan creation processing.

BATCH = nnnnn0

This is an optional parameter used to specify the maximum number of pre-fetch requests which are to be processed by Archive Manager in a single batch. ‘nnnnn’ is a 1-5 digit numeric value in the range 0-99999, specifying the number of requests to be processed per batch. A value of

0 indicates that there is no maximum to the size of the request batch – all rows identified for pre-fetching during execution of the utility will be processed in a single batch. If this parameter is omitted, a default value of 0 is used.

INDEXONLY=YN

This optional parameter is used to control whether the selection criteria specified by the user for pre-fetching rows are to be capable of resolution via table indexes only. The default value of “Y” indicates that the selection criteria must be capable of resolution via indexes only. If this is not the case, the program will issue an error message and terminate with a condition code 12. A value of “N” indicates that the selection criteria do not need to be capable of resolution via indexes only. In this case, execution of the pre-fetch job may cause the utility to sequentially process all migrated rows from the Archive Manager database.

If this parameter is omitted, the default value of “Y” is used.

PRINT=DETAILSUMMARY

This is an optional parameter which is used to control the level of reporting performed by the utility. If a value of SUMMARY is specified for this parameter, the detailed processing report will be omitted. All other print reports will be produced as normal. If the default value of DETAIL is specified, all print reports (including the detailed processing report) will be produced.

SQLIN entry specification

The SQLIN file is a fixed-block sequential dataset with a logical record length of 80 bytes. It must contain one or more records containing a free-format text description of the rule(s) to be used for selection of rows to be pre-fetched by Archive Manager. Character positions 1-71 will be used for this description.

102

DB2 Manager User Guide

 

StorageTek Proprietary

Page 105
Image 105
StorageTek 312564001 manual SQLIN entry specification, PLAN=xxxxxxxx