Reason code Explanation (hex)
Action: Refer to IBM documentation on the LOCASCB macro for a description of the error. Take the appropriate corrective action before continuing with DB2 Manager processing.
0A00 | A request has been unable to obtain exclusive access to the DB2 | ||
| Manager control region scheduler lock within the time interval set in | ||
| the READTIMEOUT or WRITETIMEOUT initialization parameter | ||
| (depending on type of request). | ||
| Action: | This condition normally indicates a problem with the | |
|
|
| control region. Issue a series of operator summary |
|
|
| display commands (see page 51) to display the current |
|
|
| condition of the scheduler lock. If this indicates that it is |
|
|
| unlocked, |
|
|
| review the control region joblog for other error messages. |
|
|
| If no reason for the error can be identified, report the |
|
|
| problem to your local DB2 Manager support |
|
|
| representative. To relieve the condition, perform an |
|
|
| immediate stop on the control region and restart the |
|
|
| region. |
0B00 | A migrated row has been accessed by the row migration utility | ||
| OTDBP100. | ||
| Action: | This is a normal condition when running an DB2 Manager | |
|
|
| utility program, and will be handled by the program. This |
|
|
| error should not occur when executing any other type of |
|
|
| program. |
0C00 | Field TCBUSER was not correctly initialized during DB2 Manager | ||
| utility processing. The utility job will terminate with an error. | ||
| Action: | This indicates an internal DB2 Manager error. Report the | |
|
|
| problem to your local DB2 Manager support |
|
|
| representative. |
0Dxx | A problem has occurred attempting to communicate with the DB2 | ||
| Manager control region. The second byte of the reason code (‘xx’) | ||
| will contain a | ||
| 01 - | An invalid DB2 Manager communications table was found by the | |
|
| row edit procedure OTDBP300. | |
|
| Action: This indicates an internal error in DB2 Manager | |
|
|
| processing. Stop and restart the control region to try to |
|
|
| clear the error condition. If this does not work, report the |
|
|
| problem to your local DB2 Manager support |
|
|
| representative. |
| 02 - | The name of the DB2 Manager control region held in the ASCB | |
|
| addressed by the row edit procedure OTDBP300 does not | |
|
| match that of the control region at | |
|
| Action: This indicates an internal error in DB2 Manager | |
168 |
|
| DB2 Manager User Guide |
|
|
| StorageTek Proprietary |