INSTrument Subsystem
3–78 AM700 Audio Measurement Set Programmer Manual
INSTrument:LSELect:USER <descriptive_name>
Usage: Selects an instrument (application) to run on the User button by long descriptive
name. The string data returned by INST:LCAT? provides the long descriptive
names for the applications.
Example: inst:sel:user ”Audio Monitor” selects the Audio Monitor to run on
the User button.
Query: INSTrument:LSELect:USER? returns the <descriptive_name> of the
application assigned to run on the User button.
INSTrument:LCATalog?
Usage: Gives a list of <descriptive_name> strings is a comma separated list. Applica-
tion numbers are not included.
Query: Query only. Returns a comma separated list of application name as string data.
INSTrument:LCATalog:FULL?
Usage: Gives a list of <descriptive_names> strings as in LCAT, but includes the
application number. The full name of the application and the application
number that may be used with INST:NSEL are returned in a comma separated
list.
Query: Query only. Returns long names of applications as string data.
”FFT Analyzer”,1,”Audio Analyzer”,2,”Audio
Monitor”,3,”Digital Interface Tester”,4,”Diagnos-
tics”,5,”Touch Panel Calibration”,6
INSTrument:NSELect <app_number>
Usage: Selects the application to run on the AM700 by number.
Syntax: INST:NSEL 1|2|3|4|5|6