SOURce:VOLTage Subsystem
AM700 Audio Measurement Set Programmer Manual 3–139
SOURce[1–8]:VOLTage:STOP <numeric_value>
Usage: Sets the stopping voltage for a voltage sweep.
Query: SOURce:VOLTAGE:STOP? returns the maximum level of a voltage sweep
for the designated SOURce.
*RST: Sets STOP to 2.0000. Default unit is volts.
SOURce[1–8]:VOLTage[:LEVel] <numeric_value>
Usage: Sets the voltage level of the designated source.
Query: SOURce[1–8]:VOLTage? returns the level of the fixed voltage signal for
the designated SOURce.
*RST: Sets LEVel to 0.7747 (0 dBu). Default unit is volts. If a voltage sweep is
occurring, the return follows the signal amplitude of the sweep.
SOURce[1–8]:VOLTage[:LEVel][:IMMediate] <numeric_value>
Usage: Used to indicate that the new voltage setting is to be made immediately without
waiting for further commands.
SOURce[1–8]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
<numeric_value>
Usage: Sets or queries the acutal level of the unswept output signal in terms of the
current operating units. The units are set to the default value, or alternately to a
different value under the UNIT subsystem. AMPLitude may be used to specify
the level for either a time varying or non–time varying signal. The optional
nodes are omitted for normal use with the AM700 and the numeric_value
directly follows the VOLTage keyword.