Lamp indication

Check code

Cause of trouble occurrence

 

 

 

 

 

 

 

 

 

 

Operation

Timer

Ready

F01

Heat exchanger sensor (TCJ) error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F02

Heat exchanger sensor (TC) error

Indoor unit sensor error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger sensor (TA) error

 

 

Alternate flash

 

 

P10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F04

 

 

 

 

 

 

 

 

 

 

 

 

Discharge temp. sensor (TD) error

 

 

 

 

 

 

 

 

 

F06

 

 

 

 

 

 

 

 

 

Temp. sensor (TE) error

 

 

 

Operation

Timer

Ready

F07

 

 

 

Temp. sensor (TL) error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F08

Temp. sensor (TO) error

 

Sensor error of outdoor unit

1

 

 

 

 

 

 

 

Temp. sensor (TS) error

 

 

 

Alternate flash

 

 

F12

 

 

 

 

 

Temp. sensor (TH) error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F13

Temp. Sensor miswiring (TE, TS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

Timer

Ready

 

 

 

 

 

 

 

 

 

 

 

 

F29

Indoor EEPROM error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Simultaneous flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

Timer

Ready

 

 

 

 

 

 

 

 

 

 

 

 

F31

Outdoor EEPROM error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Simultaneous flash

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H01

 

 

 

 

 

 

 

 

 

 

 

 

Compressor break down

 

 

 

Operation

Timer

Ready

H02

 

 

 

Compressor lock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H03

Current detection circuit error

Outdoor compressor system error

1

 

 

 

 

 

 

 

Case thermostat worked.

 

 

 

 

 

Flash

 

 

H04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit low pressure system error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L03

Duplicated master indoor units

 

 

 

Operation

Timer

Ready

 

There is indoor unit of group connection AUTO address

 

L07

 

in individual indoor unit.

 

* If group construction and

 

 

 

 

 

 

 

 

Unsetting of group address

 

 

 

 

 

 

 

 

 

 

 

address are not normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L08

Missed setting

 

 

when power supply turned on,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Simultaneous flash

 

(Unset indoor capacity)

 

 

automatically goes to address

 

 

 

 

 

 

L09

 

 

 

setup mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L10

Unset model type (Service board)

 

 

 

 

 

 

 

 

 

 

 

Operation

Timer

Ready

L20

 

 

Duplicated indoor central addresses

 

 

 

 

 

 

 

 

L29

Outdoor unit and other error

 

Others

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside interlock error

 

 

 

 

Simultaneous flash

L30

 

 

 

 

 

 

 

 

Negative phase error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: These are representative examples and the check code differs according to the outdoor unit to be combined.