High-temp.

1)

The heating operation is performed as follows based on the

 

 

 

release control

 

detected temperature of Tc sensor or Tcj sensor.

 

 

 

 

 

 

 

• When [M] zone is detected, the commanded frequency is

However this control is

 

 

 

decreased from the real operation frequency. After then

ignored in case of the

 

 

 

the commanded frequency changes every 30 seconds

follower unit of the twin.

 

 

 

while operation is performed in [M] zone.

 

 

 

 

 

 

 

• In [N] zone, the commanded frequency is held.

 

 

 

 

 

 

 

• When [L] zone is detected, the commanded frequency is

 

 

 

 

 

returned to the original value by approx. 6Hz every 60

 

 

 

 

 

seconds.

 

 

 

 

 

 

 

 

 

 

 

Setup at shipment

Tc (˚C)

M

 

 

 

 

 

 

 

 

Tcj A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control temp. (°C)

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56 (54)

 

52 (52)

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the operation has started or when Tc or Tcj < 30°C at

Same status as that

 

 

start of the operation or after operation start, temperature is

when “thermostat-OFF”

 

 

controlled between values in parentheses of A and B.

(status that the air

 

 

 

 

 

 

 

 

 

 

 

 

 

conditioner enters in the

 

 

 

 

 

 

 

 

 

 

 

 

room temp. monitor

 

 

 

 

 

 

 

 

 

 

 

 

mode when the

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature reached the

 

 

 

 

 

 

 

 

 

 

 

 

setup temperature on

 

 

 

 

 

 

 

 

 

 

 

 

the remote controller)

 

 

 

 

 

 

 

 

 

 

10

Drain pump

1)

In cooling operation (including Dry operation), the drain

 

 

 

control

 

pump is usually operated.

 

 

 

 

 

 

2)

If the float switch works while drain pump drives, the

Check code [P10]

 

 

 

 

compressor stops, the drain pump continues the operation,

 

 

 

 

 

 

 

 

 

and a check code is output.

 

 

 

 

 

 

3)

If the float switch works while drain pump stops, the

 

 

 

 

 

compressor stops and the drain pump operates. If the float

 

 

 

 

 

switch keeps operating for approx. 4 minutes, a check code

 

 

 

 

 

is output.

 

 

 

 

 

 

 

 

 

 

 

4)

If the humidifier “Provided” is judged, compressor [ON], fan

 

 

 

 

 

[ON] and TC sensor value > 33°C, the drain pump operates.

 

 

 

 

 

 

 

 

 

 

 

11

After-heat

When heating operation stops, in some cases, the indoor fan

[Dry operation

] is

 

elimination

operates with (L) for approx. 30 seconds.

 

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 51 –

Page 51
Image 51
Toshiba RAV-SP1404ATZ-E, RAV-SM1404UT-E, RAV-SM1104UT-E, RAV-SP1104AT-E, RAV-SP1404ATZG-E Setup at shipment, Control temp. C

RAV-SP1104ATZG-E, RAV-SP1104ATZ-E, RAV-SP1404ATZ-E, RAV-SM804UT-E, RAV-SP1404AT-E specifications

Toshiba has long been a notable player in the air conditioning market, with a range of products designed to deliver effective cooling and heating solutions. Among its recent offerings are the RAV-SP1104AT-E, RAV-SM1404UT-E, RAV-SM1104UT-E, RAV-SP1104ATZ-E, and RAV-SP1404ATZ-E models. Each of these models is engineered for efficiency, performance, and user convenience.

The RAV-SP1104AT-E is designed for residential and commercial spaces alike, featuring advanced inverter technology. This model operates efficiently by adjusting compressor speed according to the required cooling load, resulting in reduced energy consumption and optimal performance. With a cooling capacity of 11 kW, it is suitable for medium to large spaces.

The RAV-SM1404UT-E model builds on this efficiency with enhanced features aimed at maximizing comfort. It includes a built-in Wi-Fi capability, allowing users to control the system remotely through a mobile app. This model boasts a high-energy efficiency rating, which translates into lower operating costs and a smaller environmental footprint.

Similarly, the RAV-SM1104UT-E emphasizes versatility and adaptability, adept at handling various climatic conditions. In addition to its robust cooling performance, it supports heating capabilities, making it an excellent choice for year-round use. The unit's quiet operation ensures comfort without the nuisance of disruptive noise, making it ideal for both residential and commercial settings.

The RAV-SP1104ATZ-E and RAV-SP1404ATZ-E models represent the pinnacle of Toshiba's innovation in multi-split systems. Both models utilize advanced refrigerant technology, ensuring rapid cooling and heating while minimizing energy loss. The RAV-SP1104ATZ-E offers a balanced performance with a focus on high efficiency, while the RAV-SP1404ATZ-E provides greater capacity, ideal for larger establishments requiring substantial climate control.

All these units feature Toshiba's cutting-edge technologies, including advanced filtration systems that improve indoor air quality by capturing dust, allergens, and other particulates. The robust design of these models ensures durability and longevity, making them a worthwhile investment for any property owner.

In summary, Toshiba’s RAV-SP1104AT-E, RAV-SM1404UT-E, RAV-SM1104UT-E, RAV-SP1104ATZ-E, and RAV-SP1404ATZ-E models reflect the brand's commitment to innovation and energy efficiency. These air conditioning solutions cater to a variety of needs while ensuring comfort, reduced environmental impact, and user-friendly operation.