Toshiba VF-S11 manual E6581160

Models: VF-S11

1 81
Download 81 pages 58.25 Kb
Page 58
Image 58
Manual background

 

 

 

 

 

 

 

 

 

E6581160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication

 

 

Minimum

 

 

 

 

 

 

 

 

 

Title

Function

Unit

setting unit

Adjustment range

Default

User

 

Reference

 

 

No.

Panel/Commun

setting

setting

 

E6581158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

 

 

 

H

0307

Supply voltage

-

-

0: Supply voltage uncorrected, output

2

 

 

6.13.6

 

 

 

 

 

 

correction

 

 

voltage limited

(WP, WN)

 

 

 

 

 

 

 

 

 

(limitation of

 

 

1: Supply voltage corrected, output

3 (AN)

 

 

 

 

 

 

 

 

 

output voltage)

 

 

voltage limited

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Supply voltage uncorrected, output

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage unlimited

 

 

 

 

 

 

 

 

 

 

 

 

 

3: Supply voltage corrected, output

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage unlimited

 

 

 

 

 

 

 

 

H

0308

Dynamic braking

0.1/0.1

1.0-1000

* 1

 

 

6.13.4

 

 

 

 

 

 

resistance

 

 

 

 

 

 

 

 

 

 

 

H

0309

Dynamic braking

kW

0.01/0.01

0.01-30.00

* 1

 

 

6.13.4

 

 

 

 

 

 

resistor capacity

 

 

 

 

 

 

 

 

 

 

 

H

0311

Reverse-run

-

-

0: Forward/reverse run permitted

0

 

 

6.13.7

 

 

 

 

 

 

prohibition

 

 

1: Reverse run prohibited

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Forward run prohibited

 

 

 

 

 

 

 

 

H

0312

Random mode

-

-

0: Disabled

0

 

 

6.12

 

 

 

 

 

 

 

 

 

1: Automatic setting

 

 

 

 

 

 

 

 

H

0316

Carrier frequency

-

-

0: Carrier frequency not reduced

1

 

 

6.12

 

 

 

 

 

 

control mode

 

 

automatically

 

 

 

 

 

 

 

 

 

 

selection

 

 

1: Carrier frequency reduced

 

 

 

 

 

 

 

 

 

 

 

 

 

automatically

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Carrier frequency not reduced

 

 

 

 

 

 

 

 

 

 

 

 

 

automatically

 

 

 

 

 

 

 

 

 

 

 

 

 

Support for 500V/600V models

 

 

 

 

 

 

 

 

 

 

 

 

 

3: Carrier frequency reduced

 

 

 

 

 

 

7

 

 

 

 

 

 

automatically

 

 

 

 

 

 

 

 

 

 

 

 

Support for 500V/600V models

 

 

 

 

 

 

H

0320

Droop gain

1/1

0-100

0

 

 

6.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0323

Droop insensitive

1/1

0-100

10

 

 

6.14

 

 

 

 

 

 

torque band

 

 

 

 

 

 

 

 

 

 

 

H

0342

Braking mode

-

-

0: Disabled

0

 

 

6.15

 

 

 

 

 

 

selection

 

 

1: Enabled (forward run)

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Enabled (reverse run)

 

 

 

 

 

 

 

 

 

 

 

 

 

3: Enabled (operating direction)

 

 

 

 

 

 

 

 

H

0343

Release

Hz

0.1/0.01

H-20.0

3.0

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

H

0344

Release time

s

0.01/0.01

0.00-2.50

0.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0345

Creeping

Hz

0.1/0.01

H-20.0

3.0

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

H

0346

Creeping time

s

0.01/0.01

0.00-2.50

0.10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0359

PID control

s

1/1

0-2400

0

 

 

6.16

 

 

 

 

 

 

waiting time

 

 

 

 

 

 

 

 

 

 

 

H

0360

PID control

-

-

0: Disabled, 1: Enabled

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0362

Proportional gain

-

0.01/0.01

0.01-100.0

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0363

Integral gain

-

0.01/0.01

0.01-100.0

0.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

0366

Differential gain

-

0.01/0.01

0.00-2.5

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 : Default values vary depending on the capacity. See the table of 64.

57

Page 58
Image 58
Toshiba VF-S11 manual E6581160