E6581160

Output parameters

 

Communication

 

 

Minimum

 

 

 

 

 

 

 

Title

Function

Unit

setting unit

 

Adjustment range

Default

User

Reference

 

No.

Panel/Commun

 

setting

setting

E6581158

 

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

 

H

0669

Logic output/pulse

-

-

0: Logic output

0

 

6.20.1

 

 

 

 

train output

 

 

1: Pulse train output

 

 

 

 

 

 

 

selection (OUT-

 

 

 

 

 

 

 

 

 

 

 

NO)

 

 

 

 

 

 

 

 

 

H

0676

Pulse train output

-

-

0:

Output frequency

0

 

6.20.1

 

 

 

 

function selection

 

 

1:

Output current

 

 

 

 

 

 

 

(OUT-NO)

 

 

2:

Set frequency

 

 

 

 

 

 

 

 

 

 

3:

DC voltage

 

 

 

 

 

 

 

 

 

 

4:

Output voltage command value

 

 

 

 

 

 

 

 

 

 

5:

Input power

 

 

 

 

 

 

 

 

 

 

6:

Output power

 

 

 

 

 

 

 

 

 

 

7:

Torque

 

 

 

 

 

 

 

 

 

 

8:

Torque current

 

 

 

 

 

 

 

 

 

 

9:

Motor cumulative load factor

 

 

 

 

 

 

 

 

 

 

10: Inverter cumulative load factor

 

 

 

 

 

 

 

 

 

 

11: PBR (braking reactor) cumulative

 

 

 

 

 

 

 

 

 

 

 

load factor

 

 

 

 

 

 

 

 

 

 

12: Frequency setting value (after

 

 

 

 

 

 

 

 

 

 

 

PID)

 

 

 

 

 

 

 

 

 

 

13: VIA/II Input value

 

 

 

 

 

 

 

 

 

 

14: VIB Input value

 

 

 

 

 

 

 

 

 

 

15: Fixed output 1 (Output current:

 

 

 

 

 

 

 

 

 

 

 

100%)

 

 

 

 

 

 

 

 

 

 

16: Fixed output 2 (Output current:

 

 

 

 

7

 

 

 

 

 

 

50%)

 

 

 

 

 

 

 

 

 

17: Fixed output 3

 

 

 

 

 

 

 

 

 

 

(Other than the output current:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%)

 

 

 

 

 

H

0677

Maximum numbers

pps

1/1

500-1600

800

 

6.20.1

 

 

 

 

of pulse train

 

 

 

 

 

 

 

 

 

H

0691

Inclination

-

-

0: Negative inclination (downward

1

 

6.20.2

 

 

 

 

characteristic of

 

 

slope)

 

 

 

 

 

 

 

analog output

 

 

1: Positive inclination (upward slope)

 

 

 

 

 

H

0692

Meter bias

%

1/1

0100

0

 

6.20.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation panel parameters

 

Communication

 

 

Minimum

 

 

 

 

Title

Function

Unit

setting unit

Adjustment range

Default

User

Reference

No.

Panel/Commun

setting

setting

E6581158

 

 

 

 

 

 

 

 

ication

 

 

 

 

H

0700

Prohibition of

-

-

0: Permitted

0

 

6.21.1

 

 

change of

 

 

1: Prohibited

 

 

 

 

 

parameter settings

 

 

 

 

 

 

H

0701

Unit selection

-

-

0: %

0

 

6.21.2

 

 

 

 

 

1: A (ampere)/V (volt)

 

 

 

H

0702

Free unit selection

Times

0.01/0.01

0.00: Free unit display disabled

0.00

 

6.21.3

 

 

 

 

 

(display of frequency)

 

 

 

 

 

 

 

 

0.01-200.0

 

 

 

H

0705

Inclination

-

-

0: Negative inclination (downward

1

 

 

 

 

characteristic of

 

 

slope)

 

 

 

 

 

free unit display

 

 

1: Positive inclination (upward slope)

 

 

 

H

0706

Free unit display

Hz

0.01/0.01

0.00-HJ

0.00

 

 

 

 

bias

 

 

 

 

 

 

H

0707

Free step 1

Hz

0.01/0.01

0.00: Disabled

0.00

 

6.21.4

 

 

(pressing a panel

 

 

0.01-HJ

 

 

 

 

 

key once)

 

 

 

 

 

 

H

0708

Free step 2 (panel

-

1/1

0: Disabled

0

 

 

 

 

display)

 

 

1-255

 

 

 

61

Page 62
Image 62
Toshiba VF-S11 manual Output parameters, Operation panel parameters