E6581160
4.2.2How to set extended parameters
The
All extended parameters are expressed with H and three digits.
Basic parameters
H
ENT
MODE
H~H
4
Press the MODE key once and use the VW key to select H from the basic parameters.
[Steps in key entry for extended parameters]
Press the V key or the W key to change the set value. Pressing the ENTER key allows the reading of parameter setting.
|
| : switches to the setting monitor mode.(Displays CWJ) |
|
MODE |
| * See 7.3 for extended | |
|
|
| parameters. |
:Selects "H" from basic parameters.
:The first extended parameter “HK”
:Selects the extended parameter whose setting needs to be changed.
:Reads the programmed parameter setting.
: Changes the parameter setting.
Saves the changed value of the extended parameter setting.
Pressing the MODE key instead of the key moves back to the previous status.
31