![](/images/new-backgrounds/1093940/9394073x1.webp)
E6581160
5. Monitoring the operation status
Refer to 4.1 about flow of monitor.
5.1Status monitor mode
5.1.1Status monitor under normal conditions
In this mode, you can monitor the operation status of the inverter.
To display the operation status during normal operation:
Press the MODE key twice.
Setting procedure (eg. operation at 60Hz)
|
|
|
|
| Item displayed |
| Key | LED | Communic | Description | |
5 |
|
|
|
| operated | display | ation No. | ||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| . |
| The operation frequency is displayed (Operation at | |
|
|
|
|
|
|
|
|
|
| 60Hz). (When standard monitor display selection | |
|
|
|
|
|
|
|
|
|
|
| H is set at 0 [operation frequency]) |
|
|
|
|
| Parameter setting |
| MODE | CWJ |
| The first basic parameter “CWJ” (history function) | |
|
|
|
|
| mode |
|
| is displayed. | |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Direction of |
| MODE | HTH | FE01 | The direction of rotation is displayed. | |
|
|
|
|
| rotation |
| (HTH: forward run, HTT: reverse run) | ||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Operation |
|
|
|
|
| The operation frequency command value (Hz/free |
|
|
|
|
|
|
|
|
|
| ||
|
| Note 1 |
|
|
|
|
|
| |||
|
|
| frequency |
|
|
| H | FE02 | unit) is displayed. | ||
|
|
|
|
|
|
|
| ||||
|
|
|
|
| command |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The inverter output current (load current) (%/A) is |
|
|
|
|
|
|
|
|
|
|
| |
|
| Note 2 |
| Load current |
|
|
| E | FE03 | ||
|
|
|
|
|
| displayed. | |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Input voltage |
|
|
|
| FE04 | The inverter input (DC) voltage (%/V) is displayed. | |
|
| Note 3 |
|
|
| [ | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Output voltage |
|
|
| R | FE05 | The inverter output voltage (%/V) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Torque |
|
|
| SQ | FE18 | The torque (%) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Torque current |
|
|
| Y | FE20 | The torque current (%/A) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inverter load factor |
|
|
| N | FE27 | The inverter load factor (%) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PBR cumulative |
|
|
| T | FE25 | The cumulative load factor of the braking resistor |
|
|
|
|
| load factor |
|
|
| (%) is displayed. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Input power |
|
|
| k | FE29 | The inverter input power (kW) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Output power |
|
|
| J | FE30 | The inverter output power (kW) is displayed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Operation |
|
|
| Z | FD00 | The operation frequency (Hz/free unit) is |
|
|
|
|
| frequency |
|
|
| displayed. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
(Continued overleaf)
36