Toshiba VF-S11 manual 4.2.7How to save/load the user setting parameters, E6581160

Models: VF-S11

1 81
Download 81 pages 58.25 Kb
Page 36
Image 36
4.2.7How to save/load the user setting parameters

E6581160

4.2.6Returning all parameters to standard default setting

Setting the standard default setting parameter V[R=, all parameters can be returned to the those factory default settings.

Note: For more details on the standard default setting parameter V[R, see 5.6.

Notes on operation

We recommend that before this operation you write down on paper the values of those parameters,

because when setting V[R=, all parameters with changed values will be returned to standard factory default setting.

Note that HO, HOUN, H, f470-f473, H and H will not be reset to their

factory default settings.

4

 

 

 

QSteps for returning all parameters to standard default setting

Key operated

LED display

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 



Displays the operation frequency (perform during operation stopped).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The first basic parameter “CWJ” (history function) is displayed.

 

 

MODE

 

 

 

CWJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V[R

Press the

 

 

key or the

 

 

key to change to V[R.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressing the ENTER key displays the programmed parameters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 





(V[R will always display "(zero)" on the right, the previous setting

 

 

 

 

 

 

 

 

on the left.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 





Press the

 

key or the

 

key to change the set value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To return to standard factory default setting, change to "".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KPKV

Pressing the ENTER key displays "KPKV" while returning all

 

 

 

 

 

 

parameters to factory default setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



The monitor returns to the display of setup parameters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If there is anything you do not understand during this operation, press the MODE key several times to start over from the step of CWJ display.

4.2.7How to save/load the user setting parameters

The current settings of all parameters can be stored (saved) in memory at a time by setting the standard setting mode selection parameter V[p to 7. Also, all parameter settings stored in memory can be restored (loaded) by setting parameter V[p to 8. This means that you can use this parameter (V[p=7 and 8) as the parameter for your own initial settings (default settings).

35

Page 36
Image 36