QTable of output terminal functions 3

Function

Code

Function

Action

 

 

No.

 

 

 

 

 

 

 

35

FCVIBN

Inversion of frequency VIB selection

Inversion of FCVIB

 

 

36

FLR

Fault signal (put out also at the time of a retry)

ON: When inverter trips or retries

 

 

 

 

 

OFF: When inverter does not trip or retry

 

 

37

FLRN

Inversion of failure signal (put out also at the time

Inversion of FLR

 

 

 

 

of a retry)

 

 

 

38

OUT0

Specified data output 1

ON: Specified data from remote control FA50:

 

 

 

 

 

BIT0= 1

 

 

 

 

 

OFF: Specified data from remote control FA50:

 

 

 

 

 

BIT0= 0

 

 

39

OUT0N

Inversion of specified data output 1

Inversion of OUT0 setting

 

 

40

OUT1

Specified data output 2

ON: Specified data from remote control FA50:

 

 

 

 

 

BIT1= 1

 

 

 

 

 

OFF: Specified data from remote control FA50:

 

 

 

 

 

BIT1= 0

 

 

41

OUT1N

Inversion of specified data output 2

Inversion of OUT1 setting

 

 

42

COT

Cumulative operation time alarm

ON: Cumulative operation time is equal to or

 

 

 

 

 

longer than H

 

 

 

 

 

OFF: Cumulative operation time is shorter than

 

 

 

 

 

H

 

 

43

COTN

Inversion of cumulative operation time alarm

Inversion of COT

 

 

44

LTA

Parts replacement alarm

ON: Calculation for parts replacement time is

 

 

 

 

 

equal to or longer than the preset time

 

 

 

 

 

ON: Calculation for parts replancement time is

 

 

 

 

 

shorter than the preset time

 

 

45

LTAN

Inversion of replacement alarm

Inversion of LTA

 

 

7

46

BR

Braking sequence output

ON: Braking retention signal

 

 

 

 

OFF: Braking release signal

 

47

BRN

Inversion of braking sequence output

Inversion of BR

 

 

 

 

 

 

 

48

LI1

F terminal input signal

ON: The signal input to F terminal is ON

 

 

 

 

OFF: The signal input to F terminal is OFF

 

 

49

LI1N

Inversion of F terminal input signal

Inversion of LI1

 

 

50

LI2

R terminal input signal

ON: The signal input to R terminal is ON

 

 

 

 

 

OFF: The signal input to R terminal is OFF

 

 

51

LI2N

Inversion of R terminal input signal

Inversion of LI2

 

 

52

PIDF

Signal in accordance of frequency command

ON: Frequency commanded by HOQF or

 

 

 

 

 

H and that by VIA show the same

 

 

 

 

 

value.

 

 

 

 

 

OFF: Frequency commanded by HOQF or

 

 

 

 

 

H and that by VIA show different

 

 

 

 

 

values.

 

 

53

PIDFN

Inversion of signal in accordance of frequency

Inversion of PIDF setting

 

 

 

 

command

 

 

 

54

MOFF

Undervoltage detection

ON: Undervoltage detected

 

 

 

 

 

OFF: Other than undervoltage

 

 

55

MOFFN

Inversion of undervoltage detection

Inversion of MOFF

 

 

56-253

Disabled

Invalid settings, always OFF (ignored)

Invalid settings, always OFF (ignored)

 

 

254

AOFF

Always OFF

Always OFF

 

 

255

AON

Always ON

Always ON

 

 

69